RE: [IBIS-Users] pull-up/down and schmitt trigger modeling issue


Subject: RE: [IBIS-Users] pull-up/down and schmitt trigger modeling issue
From: Eric Hsu (ehsu@netlogicmicro.com)
Date: Fri Mar 28 2003 - 13:43:03 PST


Hi Tom,

Thanks for answering. Maybe I didn't describe question clearly. The pull-up/down case I mean is under buffer be tristate condition, pad might be needed to pull-up/down weakly.
As for schmitt trigger input buffer, does ibis spec. allow input buffer with and without schmitt trigger (if it could be enable/disable) feature in one single model? which mean it could be defined Vinh/Vinl (disable case) and Vinh+,Vinh-/Vinl+,Vinl- (enable case) together?

Best Regards,

Eric Hsu
Interface Technologies
NetLogic Microsystems Inc.
450 National Ave.
Mountain View, CA 94043
650-961-6676 x198

-----Original Message-----
From: Tom Dagostino [mailto:tom@teraspeed.com]
Sent: Friday, March 28, 2003 1:25 PM
To: Eric Hsu
Subject: RE: [IBIS-Users] pull-up/down and schmitt trigger modeling
issue

Eric

IBIS assumes for the Output, Tri-state and I/O buffer that both pullup and pulldown are present. If not the open sink or open source buffer types are used. ECL has its own buffer type.

Input with schmitt trigger characteristics can be specified in the Model Spec section.

Tom Dagostino
Teraspeed Consulting Group LLC Teraspeed Consulting Group LLC
2926 SE Yamhill St. Device Modeling Division
Portland, OR 97214 13610 SW Harness Lane
                                   Beaverton, OR 97008
http://www.teraspeed.com 503-430-1065
tom@teraspeed.com

-----Original Message-----
From: owner-ibis-users@server.eda.org
[mailto:owner-ibis-users@server.eda.org]On Behalf Of Eric Hsu
Sent: Friday, March 28, 2003 11:27 AM
To: ibis-users@server.eda.org
Subject: [IBIS-Users] pull-up/down and schmitt trigger modeling issue

Hi,

In the IBIS spec., is there any key word designed for output buffer if it have pullup/pulldown feature? also the same question for input buffer with schmitt trigger option?

Best Regards,

Eric Hsu
Interface Technologies
NetLogic Microsystems Inc.
450 National Ave.
Mountain View, CA 94043
650-961-6676 x198

|------------------------------------------------------------------
|For help or to subscribe/unsubscribe, email majordomo@eda.org
|with just the appropriate command message(s) in the body:
|
| help
| subscribe ibis <optional e-mail address, if different>
| subscribe ibis-users <optional e-mail address, if different>
| unsubscribe ibis <optional e-mail address, if different>
| unsubscribe ibis-users <optional e-mail address, if different>
|
|or email a written request to ibis-request@eda.org.
|
|IBIS reflector archives exist under:
|
| http://www.eda.org/pub/ibis/email_archive/ Recent
| http://www.eda.org/pub/ibis/users_archive/ Recent
| http://www.eda.org/pub/ibis/email/ E-mail since 1993
|------------------------------------------------------------------
|For help or to subscribe/unsubscribe, email majordomo@eda.org
|with just the appropriate command message(s) in the body:
|
| help
| subscribe ibis <optional e-mail address, if different>
| subscribe ibis-users <optional e-mail address, if different>
| unsubscribe ibis <optional e-mail address, if different>
| unsubscribe ibis-users <optional e-mail address, if different>
|
|or email a written request to ibis-request@eda.org.
|
|IBIS reflector archives exist under:
|
| http://www.eda.org/pub/ibis/email_archive/ Recent
| http://www.eda.org/pub/ibis/users_archive/ Recent
| http://www.eda.org/pub/ibis/email/ E-mail since 1993



This archive was generated by hypermail 2b28 : Fri Mar 28 2003 - 13:45:48 PST