Hello Shulong:
Yes BUG82 should be fixed since Ver 4.0.2 served as the
baseline for Versio 4.1X developement underway.
Bob
slwu wrote:
> Hi All,
>
> Does anybody know whether BUG82 is also fixed in ibischk4 Version 4.1.0beta
> ?
>
> Thanks
> slwu
>
> Bob Ross wrote:
>
>
>>Fabrizio:
>>
>>The difference between ibischk4 Version 4.0.1 and ibischk4 Version 4.0.1
>>is BUG82. BUG82 was serious enough to justify a special release of
>>ibischk4.
>>
>> http://eda.org/pub/ibis/bugs/ibischk/index.html
>>
>>A text list of what verion a bug fix has been implemented exists
>>in the bugdir.txt file link at the end of this link.
>>
>>Bob
>>
>>Zanella, Fabrizio wrote:
>>
>>
>>>The latest version of Synopsys Hspice, version 2004.09, uses the
>>>ibischk4 tool, version 4.0.1. In a simulation I ran yesterday, Hspice
>>>reported errors running the v4.0.1 ibischk4 with the rising and falling
>>>waveforms when using an IBIS model as a driver.
>>>
>>>Here?s a sample of the errors:
>>>
>>>ERROR - Model osoc2_od: The [Rising Waveform]
>>>
>>> with [R_fixture]=60 Ohms and [V_fixture]=3.3V
>>>
>>> has TYP column DC endpoints of 2.02V and 3.30v, but
>>>
>>> an equivalent load applied to the model's I-V tables yields
>>>
>>> different voltages ( 2.02V and 2.02V),
>>>
>>> a difference of inf% and inf%, respectively.
>>>
>>>ERROR - Model osoc2_od: The [Falling Waveform]
>>>
>>> with [R_fixture]=60 Ohms and [V_fixture]=3.3V
>>>
>>> has TYP column DC endpoints of 2.02V and 3.30v, but
>>>
>>> an equivalent load applied to the model's I-V tables yields
>>>
>>> different voltages ( 2.02V and 2.02V),
>>>
>>> a difference of inf% and inf%, respectively.
>>>
>>>
>>>
>>>An engineer at the device manufacturer said there are no errors when he
>>>uses the ibischk4 v4.0.2 tool. Can someone explain what the differences
>>>are between versions 4.0.1 and 4.0.2 of the ibischk4 tool and does
>>>anyone know whether Synopsys will be moving to the latest ibischk4 tool
>>>in the Hspice simulator?
>>>
>>>Thanks and regards,
>>>
>>>
>>>
>>>Fabrizio Zanella
>>>
>>>Signal Integrity
>>>
>>>Enterasys Networks
>>>
>>>Andover, MA
>>>
>>>Phone: 978-684-1340
>>>
>>>fzanella@enterasys.com <mailto:fzanella@enterasys.com>
-- Bob Ross Teraspeed Consulting Group LLC Teraspeed Labs 121 North River Drive 13610 SW Harness Lane Narragansett, RI 02882 Beaverton, OR 97008 503-750-6481 503-430-1065 http://www.teraspeed.com 503-246-8048 Direct bob@teraspeed.com |------------------------------------------------------------------ |For help or to subscribe/unsubscribe, email majordomo@eda.org |with just the appropriate command message(s) in the body: | | help | subscribe ibis <optional e-mail address, if different> | subscribe ibis-users <optional e-mail address, if different> | unsubscribe ibis <optional e-mail address, if different> | unsubscribe ibis-users <optional e-mail address, if different> | |or email a written request to ibis-request@eda.org. | |IBIS reflector archives exist under: | | http://www.eda.org/pub/ibis/email_archive/ Recent | http://www.eda.org/pub/ibis/users_archive/ Recent | http://www.eda.org/pub/ibis/email/ E-mail since 1993Received on Mon Dec 20 21:52:58 2004
This archive was generated by hypermail 2.1.8 : Mon Dec 20 2004 - 21:54:26 PST