Hello : I just tried running my open-drain IBIS model using latest 4.1 parser (just released), and found major errors like shown below. However my model passed clean using version 3.2 and 4.0.2 parsers. Let me know if anyone else has similar errors with 4.1 which were not flagged on previous parser, and whether 4.1 is correct with these errors. I'm just surprised that 4.0.2 and 3.2 passed the same model. Thanks! ------------- Begin Forwarded Message ------------- IBISCHK4 V4.1.0 Checking drac_tc260_150.ibs for IBIS 4.1 Compatibility... ERROR - Model DRAC_TC260: The [Falling Waveform] with [R_fixture]=34 Ohms and [V_fixture]=1.8V has TYP column DC endpoints of 1.01V and 1.80v, but an equivalent load applied to the model's I-V tables yields different voltages ( 1.01V and 0.00V), a difference of 0.01% and 178.36%, respectively. (this was clean with old Parser 3.2 and 4.0.2) ------------- End Forwarded Message ------------- |------------------------------------------------------------------ |For help or to subscribe/unsubscribe, email majordomo@eda.org |with just the appropriate command message(s) in the body: | | help | subscribe ibis <optional e-mail address, if different> | subscribe ibis-users <optional e-mail address, if different> | unsubscribe ibis <optional e-mail address, if different> | unsubscribe ibis-users <optional e-mail address, if different> | |or email a written request to ibis-request@eda.org. | |IBIS reflector archives exist under: | | http://www.eda.org/pub/ibis/email_archive/ Recent | http://www.eda.org/pub/ibis/users_archive/ Recent | http://www.eda.org/pub/ibis/email/ E-mail since 1993Received on Thu Mar 17 12:32:52 2005
This archive was generated by hypermail 2.1.8 : Thu Mar 17 2005 - 12:35:38 PST