> > Hello Friends, As I read in IBIS standard Voltage Range----Defines the power supply voltage tolerance over which the model is intended to operate. Pullup Reference--Defines a voltage rail other than that defined by the [Voltage Range] keyword as the reference voltage for the [Pullup] I-V data. My buffer have dual supply VDD and VDDE2V5. VDD is the core side supply and VDDE2V5 voltage at the pad as well as voltage at the pullup and power clam diode. I wnat to know how this information is use in the simulation. When pullup information is present then it's overwrite voltag information? I have given [Voltage Range] 1.2 1.1 1.3 [Pullup Reference] 2.5 2.2 2.7 Which information is used in the simulation. Regards Akhilesh |------------------------------------------------------------------ |For help or to subscribe/unsubscribe, email majordomo@eda.org |with just the appropriate command message(s) in the body: | | help | subscribe ibis <optional e-mail address, if different> | subscribe ibis-users <optional e-mail address, if different> | unsubscribe ibis <optional e-mail address, if different> | unsubscribe ibis-users <optional e-mail address, if different> | |or email a written request to ibis-request@eda.org. | |IBIS reflector archives exist under: | | http://www.eda.org/pub/ibis/email_archive/ Recent | http://www.eda.org/pub/ibis/users_archive/ Recent | http://www.eda.org/pub/ibis/email/ E-mail since 1993Received on Thu Apr 21 06:56:15 2005
This archive was generated by hypermail 2.1.8 : Thu Apr 21 2005 - 07:01:37 PDT