Hi , On running the IBISCHK4 on a generated IBIS model, I get the following error : ERROR - Model K3B07LG24Q7_QQ60: The [Rising Waveform] with [R_fixture]=100 Ohms and [V_fixture_max]=0V has MAX column DC endpoints of 0.00V and 3.46v, but an equivalent load applied to the model's I-V tables yields different voltages ( 0.00V and 4.23V), a difference of 0.03% and 18.33%, respectively. ERROR - Model K3B07LG24Q7_QQ60: The [Rising Waveform] with [R_fixture]=100 Ohms and [V_fixture_max]=3.6V has MAX column DC endpoints of 0.11V and 3.60v, but an equivalent load applied to the model's I-V tables yields different voltages ( 0.11V and 4.40V), a difference of 0.04% and 18.69%, respectively. Can anyone guide me on the cause of this error ? And how can I get over with it ? Thanks , Vivek |------------------------------------------------------------------ |For help or to subscribe/unsubscribe, email majordomo@eda.org |with just the appropriate command message(s) in the body: | | help | subscribe ibis <optional e-mail address, if different> | subscribe ibis-users <optional e-mail address, if different> | unsubscribe ibis <optional e-mail address, if different> | unsubscribe ibis-users <optional e-mail address, if different> | |or email a written request to ibis-request@eda.org. | |IBIS reflector archives exist under: | | http://www.eda.org/pub/ibis/email_archive/ Recent | http://www.eda.org/pub/ibis/users_archive/ Recent | http://www.eda.org/pub/ibis/email/ E-mail since 1993Received on Fri May 20 03:21:12 2005
This archive was generated by hypermail 2.1.8 : Fri May 20 2005 - 03:22:23 PDT