[IBIS-Users] problem with the rising and falling waveforms

From: Vivek Kumar Sundriyal <Vivek.Kumar.Sundriyal_at_.....>
Date: Fri May 20 2005 - 03:21:57 PDT
Hi  ,

On running the IBISCHK4 on a generated IBIS model, I get the following error :

ERROR - Model K3B07LG24Q7_QQ60: The [Rising Waveform]
      with [R_fixture]=100 Ohms and [V_fixture_max]=0V
      has MAX column DC endpoints of  0.00V and  3.46v, but
      an equivalent load applied to the model's I-V tables yields
      different voltages ( 0.00V and  4.23V),
      a difference of  0.03% and 18.33%, respectively.
ERROR - Model K3B07LG24Q7_QQ60: The [Rising Waveform]
      with [R_fixture]=100 Ohms and [V_fixture_max]=3.6V
      has MAX column DC endpoints of  0.11V and  3.60v, but
      an equivalent load applied to the model's I-V tables yields
      different voltages ( 0.11V and  4.40V),
      a difference of  0.04% and 18.69%, respectively.


Can anyone guide me on the cause of this error ? And how can I get over with it
?

Thanks ,

Vivek



|------------------------------------------------------------------
|For help or to subscribe/unsubscribe, email majordomo@eda.org
|with just the appropriate command message(s) in the body:
|
|  help
|  subscribe   ibis       <optional e-mail address, if different>
|  subscribe   ibis-users <optional e-mail address, if different>
|  unsubscribe ibis       <optional e-mail address, if different>
|  unsubscribe ibis-users <optional e-mail address, if different>
|
|or email a written request to ibis-request@eda.org.
|
|IBIS reflector archives exist under:
|
|  http://www.eda.org/pub/ibis/email_archive/  Recent
|  http://www.eda.org/pub/ibis/users_archive/  Recent
|  http://www.eda.org/pub/ibis/email/          E-mail since 1993
Received on Fri May 20 03:21:12 2005

This archive was generated by hypermail 2.1.8 : Fri May 20 2005 - 03:22:23 PDT