Hi Arpad, Attached I send you the figures that show the buffer schematic and procedures I am using to extract the IBIS curves for this differential buffer and I have a few questions: If I don't specify the pullup curve, how does the IBIS simulator know how to drive a high state? If I don't specify the pullup curve, Will the IBIS parser give error messages? because it can't match the pullup curve with the rising waveform. Are these the suitable procedures to extract the IBIS curves? Thank you. Regards, Ramiro |------------------------------------------------------------------ |For help or to subscribe/unsubscribe, email majordomo@eda.org |with just the appropriate command message(s) in the body: | | help | subscribe ibis <optional e-mail address, if different> | subscribe ibis-users <optional e-mail address, if different> | unsubscribe ibis <optional e-mail address, if different> | unsubscribe ibis-users <optional e-mail address, if different> | |or email a written request to ibis-request@eda.org. | |IBIS reflector archives exist under: | | http://www.eda.org/pub/ibis/email_archive/ Recent | http://www.eda.org/pub/ibis/users_archive/ Recent | http://www.eda.org/pub/ibis/email/ E-mail since 1993