Hello Friends, Let me once and for all try to nail down an issue that seem to be a constant source of confusion. The IBIS model syntax defines the triplet order [typ] [min] [max]. But this relates to the overall case, not the individual parameter, right? So to make things match the real operational case the [min] of [Temperature Range] would really need to be the maximum temperature, right? Looking at what others do is not much help here, I see examples of both variants, frequently from the same vendor(!). So an authorative answer would be appreciated. Best regards, Lars Snith -- Those who can, Do Those who can't, Simulate -- This message has been scanned for viruses and dangerous content by MailScanner, and is believed to be clean. -------------------------------------------------------------------- |For help or to subscribe/unsubscribe, e-mail majordomo@eda-stds.org |with the appropriate command message(s) in the body: | | help | subscribe ibis <optional e-mail address, if different> | subscribe ibis-users <optional e-mail address, if different> | unsubscribe ibis <optional e-mail address, if different> | unsubscribe ibis-users <optional e-mail address, if different> | |or e-mail a request to ibis-request@eda-stds.org. | |IBIS reflector archives exist under: | | http://www.eda-stds.org/pub/ibis/email_archive/ Recent | http://www.eda-stds.org/pub/ibis/users_archive/ Recent | http://www.eda-stds.org/pub/ibis/email/ E-mail since 1993Received on Mon Mar 23 05:28:39 2009
This archive was generated by hypermail 2.1.8 : Mon Mar 23 2009 - 05:29:33 PDT