Hi
I want to  brief on the R_load  I am using

I am creating  IBIS model (Version 3.2) of a full differential buffer .
I have also  connected the termination shown in "diffbuff_termination.png" in differential buffer schematic.

Even though I have connected the required termination in schematic itself , the .s2i file need R_load value to be supplied.
Therefore I have used a High value resistor (R_load=100G ohm) in .s2i file.

Hyperlinx "Check file for IBIS spec conformance"  gives following  error ...

ERROR: Model OUTPUT_DIF: The [Rising Waveform]
      with [R_fixture]=1e+011 Ohms and [V_fixture_max]=0.22V
      has MAX column DC endpoints of  0.08V and  0.31v, but
      an equivalent load applied to the model's I-V tables yields
      different voltages ( 0.08V and  0.35V),
      a difference of  0.01% and 16.09%, respectively.

What could be wrong? What can I do to get rid of these errors and warnings?

Please mail me if any more clarification required ,Waiting for your replies.
Thanks and regards
Saravanan.G


From: Saravanan Ganesh
Sent: Thursday, May 08, 2014 8:04 PM
To: 'ibis-users@eda.org'
Subject: full differential buffer IBIS modeling

Hi
I am creating  IBIS model (Version 3.2) of a full differential buffer .
I have also  connected the termination shown in "diffbuff_termination.png" in differential buffer schematic. Therefore  I took R_load = 100G ohm in .s2i file, so that only load in schematic are effective.
Hyperlinx "Check file for IBIS spec conformance"  gives following  error ...

ERROR: Model OUTPUT_DIF: The [Rising Waveform]
      with [R_fixture]=1e+011 Ohms and [V_fixture_max]=0.22V
      has MAX column DC endpoints of  0.08V and  0.31v, but
      an equivalent load applied to the model's I-V tables yields
      different voltages ( 0.08V and  0.35V),
      a difference of  0.01% and 16.09%, respectively.

What could be wrong? What can I do to get rid of these errors and warnings?

Thanks and regards
Saravanan.G

-- 
This message has been scanned for viruses and
dangerous content by MailScanner, and is
believed to be clean.



--------------------------------------------------------------------
|For help or to subscribe/unsubscribe, e-mail mikelabonte@eda-stds.org
|or ibis-request@eda-stds.org
|
|IBIS reflector archives exist under:
|
|  http://www.eda-stds.org/ibis/email_archive/ Recent
|  http://www.eda-stds.org/ibis/users_archive/ Recent
|  http://www.eda-stds.org/ibis/email/         E-mail since 1993
diffbuff_termination.png
Received on Fri May 9 06:55:44 2014

This archive was generated by hypermail 2.1.8 : Fri May 09 2014 - 06:56:24 PDT