Hi Sebastien:

   Your best course of action would be to contact the manufacture directly.

  Regards,
  Stephen Peters
  Intel Corp.



-----Original Message-----
From: Sebastien Poste [mailto:sebastien.poste@matra-def.fr]
Sent: Tuesday, October 23, 2001 11:56 PM
To: ibis-info@eda.org; ibis-users@eda.org
Subject: MPC 755 Ibis Model


The current IBIS model of the MPC  755 processor provided on the Web
doesn't seem to be fully functionnal.
We have detected the following problems :

     - RLC package parameters : Typical value is less than minimal value.

     - gf_io driver model seems to be bad : fall time close to 10ns.

     - Very high ground clamp current (higher than 200A).

Is a new model of the MPC 755 avaible ?
Or could we have the list of the corrections to be applicated on this model
in order to make it work.

Thanks for you answers.