[IBIS-Users] problem in IBIS model of differential cell

From: Akhilesh CHANDRA <akhilesh.chandra@st.com>
Date: Wed Oct 27 2004 - 03:59:09 PDT

Hello experts,

I am making ibis models of differential cell in which output part is
something like this

VOA
| 50ohm 50ohm |VOB
| -----/\/\/\----|-----/\/\/\-----|
|
_|__
-- 0.5V
|
_|
\ / gnd

In this VOA and VOB are output pads and commen mode voltage is 0.5V. If
I apply any suplly on any pad then some current flow throgh 50 ohm
resistence. I am not able to understand how I model this current so that
every simulater read it. If I don't model it then there is drift in IBIS
and spice result.

Can any one help me to find out some solution.

Regards
Akhilesh

|------------------------------------------------------------------
|For help or to subscribe/unsubscribe, email majordomo@eda.org
|with just the appropriate command message(s) in the body:
|
| help
| subscribe ibis <optional e-mail address, if different>
| subscribe ibis-users <optional e-mail address, if different>
| unsubscribe ibis <optional e-mail address, if different>
| unsubscribe ibis-users <optional e-mail address, if different>
|
|or email a written request to ibis-request@eda.org.
|
|IBIS reflector archives exist under:
|
| http://www.eda.org/pub/ibis/email_archive/ Recent
| http://www.eda.org/pub/ibis/users_archive/ Recent
| http://www.eda.org/pub/ibis/email/ E-mail since 1993
Received on Wed Oct 27 03:59:24 2004