new ibischk3 V3.2.6

From: Syed Huq <shuq@cisco.com>
Date: Tue Jan 09 2001 - 16:48:32 PST

I ran a model with the NEW ibischk3 ver3.2.6 and get this:

new version:
ERROR - Model XYZ_IO: The [Rising Waveform]
      with [R_fixture]=50 Ohms and [V_fixture]=2.5V
      has TYP column DC endpoints of 0.41V and 2.50v, but
      an equivalent load applied to the model's I-V tables yields
      different voltages (-0.70V and 2.50V),

In the earlier version(V3.2.5),this would show up as a WARNING. Since now
it shows up as ERROR, the file fails.

old version:
WARNING - Model 'XYZ_IO': TYP AC Rising Endpoints ( 0.41V, 2.50V) not within
          0.042V (2%) of (-0.70V, 2.50V) on VI curves for 50 Ohms to 2.5V

Why was this changed to ERROR ?

Syed

 
Received on Tue Jan 9 16:52:18 2001