Syed,
This looks to be the implementation of BUG47, which flags extreme (greater
than 10%) IV-to-VT mismatches as errors instead of merely warnings. See the
BUG47 filing for details.
- Michael Mirmak, Intel Corp.
-----Original Message-----
From: Syed Huq [mailto:shuq@cisco.com]
Sent: Tuesday, January 09, 2001 4:49 PM
To: ibis-users@eda.org
Subject: new ibischk3 V3.2.6
I ran a model with the NEW ibischk3 ver3.2.6 and get this:
new version:
ERROR - Model XYZ_IO: The [Rising Waveform]
with [R_fixture]=50 Ohms and [V_fixture]=2.5V
has TYP column DC endpoints of 0.41V and 2.50v, but
an equivalent load applied to the model's I-V tables yields
different voltages (-0.70V and 2.50V),
In the earlier version(V3.2.5),this would show up as a WARNING. Since now
it shows up as ERROR, the file fails.
old version:
WARNING - Model 'XYZ_IO': TYP AC Rising Endpoints ( 0.41V, 2.50V) not
within
0.042V (2%) of (-0.70V, 2.50V) on VI curves for 50 Ohms to 2.5V
Why was this changed to ERROR ?
Syed
Received on Tue Jan 9 17:26:47 2001