Subject: RE: [IBIS-Users] number of waveforms
From: erik.van.der.ven@philips.com
Date: Wed May 28 2003 - 01:15:26 PDT
Dear Lynne,
Thank you for your reply.
I am trying to model a PECL output buffer.
So the output is normally terminated with 50 Ohm to Vcc-2V.
I am wondering how accurate the simulations are with an IBIS simulator if
the load differs from the reference load.
Will the accuracy incease if I add a second waveform set with different
load, or to another termination voltage?
Will the simulator produce a more acurate behavior model if I provide a
second waveform set, or does it use the waveform table that is most close
to the load to be simulated?
With kind regards,
Ir. Erik van der Ven
Room DB1032
Business Line Networking Infrastructure
Philips Semiconductors BV
Gerstweg 2
6534 AE Nijmegen
The Netherlands
Phone: +31-24-3534334
"Lynne Green" <lgreen@cadence.com>
05/27/03 06:33 PM
To: Erik van der Ven/NYM/SC/PHILIPS@EMEA2
cc:
Subject: RE: [IBIS-Users] number of waveforms
Classification:
Hi, Erik-
The typical recommendation is 4 waveforms tables at the same load (rising
to Vcc, rising to GND, falling to Vcc, falling to GND). That captures how
the pullup and pulldown transistors turn on and off, so tables at
additional loads are not needed.
Additional waveform tables are permitted (up to 100 according to the IBIS
spec). But the more tables you use, the slower a simulator will run.
- Lynne
-----Original Message-----
From: erik.van.der.ven@philips.com [mailto:erik.van.der.ven@philips.com]
Sent: Tuesday, May 27, 2003 6:43 AM
To: ibis-users@eda.org
Subject: [IBIS-Users] number of waveforms
Dear IBIS users,
It is possible to specify more than one waveform table, for instance with
different loads.
I have studied many IBIS models by semiconductor companies. All models I
have seen give only one waveform (both rising and falling).
What is the purpose of specifying more than one waveform? Does this yield
better results in the simulator if the load differs from the standard
load?
With kind regards,
Ir. Erik van der Ven
Room DB1032
Business Line Networking Infrastructure
Philips Semiconductors BV
Gerstweg 2
6534 AE Nijmegen
The Netherlands
Phone: +31-24-3534334
|------------------------------------------------------------------
|For help or to subscribe/unsubscribe, email majordomo@eda.org
|with just the appropriate command message(s) in the body:
|
| help
| subscribe ibis <optional e-mail address, if different>
| subscribe ibis-users <optional e-mail address, if different>
| unsubscribe ibis <optional e-mail address, if different>
| unsubscribe ibis-users <optional e-mail address, if different>
|
|or email a written request to ibis-request@eda.org.
|
|IBIS reflector archives exist under:
|
| http://www.eda.org/pub/ibis/email_archive/ Recent
| http://www.eda.org/pub/ibis/users_archive/ Recent
| http://www.eda.org/pub/ibis/email/ E-mail since 1993
This archive was generated by hypermail 2b28 : Wed May 28 2003 - 02:45:04 PDT