[IBIS-Users] pullup/pulldown range LVDS


Subject: [IBIS-Users] pullup/pulldown range LVDS
From: erik.van.der.ven@philips.com
Date: Mon Aug 11 2003 - 02:00:37 PDT


Dear IBIS users,

For ECL the pullup/pulldown curves only have to cover the 0-2.2V range
(relative to Vcc). This is because of the limited voltage swing, which is
centered around a DC voltage far away from the supply rails.
How about LVDS? It has a similar output swing. Is it needed to cover the
"regular" voltage range of -3.3-6.6V (for 3.3V supply)? It's rather a
waste of accuracy for the typical operation area (less points remain).

With kind regards,

Ir. Erik van der Ven
Room DB1032
Business Line Networking Infrastructure
Philips Semiconductors BV
Gerstweg 2
6534 AE Nijmegen
The Netherlands
Phone: +31-24-3534334
|------------------------------------------------------------------
|For help or to subscribe/unsubscribe, email majordomo@eda.org