Folks:
Here is a smple ecl model with correct signs (hopefully!!)
Here is an ecl pullup and pulldown example
[Pullup]
Voltage I(typ) I(min) I(max)
0.0 0 0 0
0.7 -0.2m -0.2m -0.2m
0.73 -0.4m -0.4m -0.4m
0.75 -0.8m -0.8m -0.8m
0.76 -1.2m -1.2m -1.2m
0.77 -1.6m -1.6m -1.6m
0.8 -4.4m -4.4m -4.4m
0.82 -7.6m -7.6m -7.6m
0.85 -14.2m -14.2m -14.2m
0.9 -30.0m -30.0m -30.0m
1.0 -58.0m -58.0m -58.0m
[Pulldown]
Voltage I(typ) I(min) I(max)
0.0 0 0 0
1.6 -0.2m -0.2m -0.2m
1.62 -0.4m -0.4m -0.4m
1.64 -0.6m -0.6m -0.6m
1.65 -0.8m -0.8m -0.8m
1.66 -1.2m -1.2m -1.2m
1.67 -1.6m -1.6m -1.6m
1.68 -2.4m -2.4m -2.4m
1.69 -3.2m -3.2m -3.2m
1.70 -4.4m -4.4m -4.4m
1.72 -7.4m -7.4m -7.4m
1.75 -14.2m -14.2m -14.2m
1.8 -30.5m -30.5m -30.5m
1.9 -65.0m -65.0m -65.0m
- Kumar
Received on Fri Apr 1 11:01:19 1994