sample ecl model

From: C. Kumar <cpk@cadence.com>
Date: Fri Apr 01 1994 - 10:57:45 PST

Folks:

Here is a smple ecl model with correct signs (hopefully!!)

Here is an ecl pullup and pulldown example

       [Pullup]
       Voltage I(typ) I(min) I(max)
           0.0 0 0 0
           0.7 -0.2m -0.2m -0.2m
           0.73 -0.4m -0.4m -0.4m
           0.75 -0.8m -0.8m -0.8m
           0.76 -1.2m -1.2m -1.2m
       0.77 -1.6m -1.6m -1.6m
       0.8 -4.4m -4.4m -4.4m
       0.82 -7.6m -7.6m -7.6m
       0.85 -14.2m -14.2m -14.2m
           0.9 -30.0m -30.0m -30.0m
           1.0 -58.0m -58.0m -58.0m

       [Pulldown]
       Voltage I(typ) I(min) I(max)
           0.0 0 0 0
           1.6 -0.2m -0.2m -0.2m
           1.62 -0.4m -0.4m -0.4m
           1.64 -0.6m -0.6m -0.6m
           1.65 -0.8m -0.8m -0.8m
           1.66 -1.2m -1.2m -1.2m
           1.67 -1.6m -1.6m -1.6m
           1.68 -2.4m -2.4m -2.4m
           1.69 -3.2m -3.2m -3.2m
           1.70 -4.4m -4.4m -4.4m
           1.72 -7.4m -7.4m -7.4m
           1.75 -14.2m -14.2m -14.2m
           1.8 -30.5m -30.5m -30.5m
           1.9 -65.0m -65.0m -65.0m

- Kumar
Received on Fri Apr 1 11:01:19 1994