??: Help, IBIS Warnings.

From: Daniel Wei <DanielWei@via.com.tw>
Date: Mon Dec 20 1999 - 05:46:29 PST

Increase the value specified at [Sim time] in the X.s2i file, then run
s2ibis2 again.

Daniel Wei

VIA Technologies, Inc.

-----原始郵件-----
寄件者: Chris Potts [mailto:chrisp@px.uk.com]
寄件日期: 1999年12月20日 PM 09:16
收件者: ibis@eda.org
主旨: Help, IBIS Warnings.

I am attempting to create a IBIS model of a connector used in a system, the
signals come from a Motorola Differential PECL clock device so I have been
trying to utilise the models available for this item, however, when checking
my model I get the following warnings,

WARNING - Model 'PECL_OBUF3_5': MIN AC Falling Endpoints ( 1.22V, 1.98V)
not within
          0.015V (2%) of ( 1.22V, 1.87V) on VI curves for 50 Ohms to 1V
WARNING - Model 'PECL_OBUF3_5': MIN VI curves cannot drive through
Vmeas=1.9V
          given load Rref=50 Ohms to Vref=1.3V

Does anyone have any help regarding these errors as I am at a loss, attached
is a copy of my file.

Thanks in advance

Chris Potts

Mr Chris Potts BEng(Hons).
Design Engineer
PowerX Ltd
Tel: +44 0161 286 2000 ext 201
Fax: +44 0161 286 2202
E-Mail: chrisp@px.uk.com
Received on Mon Dec 20 05:47:59 1999

This archive was generated by hypermail 2.1.8 : Fri Jun 03 2011 - 09:52:30 PDT