Katja:
I believe this is a bug in s2ibis2. However, direct
subtraction must be done carefully because subtracting
two tables with large diode currents causes loss in
numerical resolution. So extrapolating the [Pullup]
table so that it does not include the extra diode
information is often a better solution.
Bob Ross
Mentor Graphics
Katja Koller wrote:
>
> I have a question to the s2ibs tool fron NCSA:
>
> I made a tristate-model and found that the [Pullup]-curve has still a
> diode-current from vcc to 2*vcc. It is the same amount of current, that
> is present in the [GND_clamp].
> I thought due to the ibis-spec all the Diode-current has to be
> subtracted
> from the high-curves, not only the [POWER_clamp].
>
> I hope, you can help me with this,
>
> Katja Koller
>
> --