I'm sorry if I have miss a post address.
Could anyone, please, send me an official answer
about the leakage current?
I have received some local mails.
Thank you very much for your support.
Best regards,
Akimoto
------- Forwarded Message -------
From: akimoto@lsi.nec.co.jp
To: ibis-users@eda.org
Cc: yasufumi@lsi.nec.co.jp
Subject: [Q] off leak current?
Reply-To: akimoto@lsi.nec.co.jp
Date: Thu, 25 May 2000 09:38:27 +0900
I have a question about the IBIS modeling.
Where should we put the off leak current into?
1) Both CLAMP curves and PULLUP/DOWN curves?
2) Only CLAMP curves?
3) Only PULLUP/DOWN curves?
4) Nothing? (Same as resistor?)
I'm afraid how the board simulators get this information
from IBIS model.
Please, don't ask me more about the off leak current. ^_^
Best regards,
Akimoto
------- End of Forwarded Message -------
------------------------------------------------------
Akimoto Tetsuya
Design systems dep. System LSI Design Engineering Div.
NEC Electron Devices, NEC Corporation
Email:akimoto@lsi.nec.co.jp Phone:044-435-1513
Received on Thu May 25 16:39:29 2000