IBIS experts,
I am in the midst of creating numerous IBIS models for a wide variety of products. The issue that has come up is the selection of the proper junction temperature values for my 3 corners.
Given that the specified temperature for a device is -40 C to 85C.
Corner supplies are 4.5V, 5V, and 5.5V.
The package theta-ja 100 C/W.
The nominal room temperature quiescent power dissipation at 5V power supply voltage is 50 mW. theta-ja * 50mW = 5C
The nominal room temperature operating power dissipation at 5V power supply voltage is 100 mW. theta-ja * 100mW = 10C
The nominal cold power quiescent dissipation (@ -40C, 5V supply) is 40mW. theta-ja * 40mW = 4C
The nominal cold power operating dissipation (@ -40C, 5V supply) is 80mW. theta-ja * 80mW = 8C
The nominal hot power quiescent dissipation (@ 85C, 5V supply) is 60mW. theta-ja * 60mW = 6C
The nominal hot power operating dissipation (@ 85C, 5V supply) is 120mW. theta-ja * 120mW = 12C
Which option is correct?
Option 1: Create IBIS model with
-40C, 25C, and 85C temperatures
Option 2: Calculate nominal quiescent room temperature power dissipation and multiply that times the package theta-ja. Add this delta temperature to all three temperatures. In this case the IBIS temperatures are
-35C, 30C, and 90C.
Option 3: Calculate nominal quiescent room temperature power dissipation and multiply that times the package theta-ja. Add this delta temperature to the two higher temperatures. In this case the IBIS temperatures are
-40C, 30C, and 90C.
Option 4: Calculate the quiescent power dissipation at all temperatures and multiply that times theta-ja. The IBIS temperatures in this case would be
-36C, 30C, and 91C.
Option 5: Apply the mathematics of quiescent power and theta-ja to the two higher temperatures. In this case the IBIS temperatures are
-40C, 30C, and 91C.
Option 7: Apply Option 2 to operating power dissipation conditions. In this case the IBIS temperatures are
-30C, 35C, and 95C.
Option 8: Apply Option 3 to operating power dissipation conditions. In this case the IBIS temperatures are
-40C, 35C, and 95C.
Option 9: Apply Option 4 to operating power dissipation conditions. In this case the IBIS temperatures are
-32C, 35C, and 97C.
Option 10: Apply Option 5 to operating power dissipation conditions. In this case the IBIS temperatures are
-40C, 35C, and 97C.
Option 11: Add 15 deg C to -40C, 25C, and 85C or create IBIS model with
-25C, 40C, and 100C.
Option 12: Add 15 deg C to 25C and 85C or create IBIS model with
-40C, 40C, and 100C.
Bonnie
-- This message has been scanned for viruses and dangerous content by MailScanner, and is believed to be clean. -------------------------------------------------------------------- |For help or to subscribe/unsubscribe, e-mail majordomo@eda-stds.org |with the appropriate command message(s) in the body: | | help | subscribe ibis <optional e-mail address, if different> | subscribe ibis-users <optional e-mail address, if different> | unsubscribe ibis <optional e-mail address, if different> | unsubscribe ibis-users <optional e-mail address, if different> | |or e-mail a request to ibis-request@eda-stds.org. | |IBIS reflector archives exist under: | | http://www.eda-stds.org/pub/ibis/email_archive/ Recent | http://www.eda-stds.org/pub/ibis/users_archive/ Recent | http://www.eda-stds.org/pub/ibis/email/ E-mail since 1993Received on Sun Jun 26 14:23:05 2011