Hi All

I have a quection related to series switch which has terminator
model associated with it
The C_Comp value is accounted in both the switch model and terminator model
Is it necessary to account the value of C_Comp in both the buffer
model ?
I feel C_Comp value is accounted twice in this model

I have furthur quections also on this

How the C_Comp value is measured in the series switch model ?

Why Clamping curvers are required for Terminator i/p Model ?
 
Any materials availible for this kind of modelling ?

****************pin mapping in switch model **********
[Pin] signal_name model_name R_pin L_pin C_pin
|
2 1A1 TERM 0.06039 5.09918nH 0.96155pF

**************** switch model **********
[Model] SWITCH1
Model_type Series_switch
C_comp 9.000pF NA NA

****************terminator model **********
[Model] TERM
Model_type Terminator
|
C_comp 5.500pF NA NA

Regards
SUDHEER

|------------------------------------------------------------------
|For help or to subscribe/unsubscribe, email majordomo@eda.org
|with just the appropriate command message(s) in the body:
|
| help
| subscribe ibis <optional e-mail address, if different>
| subscribe ibis-users <optional e-mail address, if different>
| unsubscribe ibis <optional e-mail address, if different>
| unsubscribe ibis-users <optional e-mail address, if different>
|
|or email a written request to ibis-request@eda.org.
|
|IBIS reflector archives exist under:
|
| http://www.eda.org/pub/ibis/email_archive/ Recent
| http://www.eda.org/pub/ibis/users_archive/ Recent
| http://www.eda.org/pub/ibis/email/ E-mail since 1993



This archive was generated by hypermail 2b28 : Tue Oct 14 2003 - 00:42:16 PDT