Subject: re: [IBIS-Users] IBIS model Error
From: Lynne Green (lgreen@cadence.com)
Date: Tue Oct 14 2003 - 09:17:42 PDT
Hello Muthu Lakshmi,
You might want to let Cypress know that they can send models for review
by the IBIS Model Review Committee. More information is at
http://www.eigroup.org/ibis/support.htm.
Best regards,
Lynne
Dr. Lynne Green
Vice Chair, IBIS
Cadence Design Systems
-----Original Message-----
From: erik.van.der.ven@philips.com [mailto:erik.van.der.ven@philips.com]
Sent: Monday, July 28, 2003 4:10 AM
To: KMuthulakshmi@scmmicro.co.in; ibis-users@eda.org
Subject: Re: [IBIS-Users] IBIS model Error
Hello Muthu Lakshmi,
I think there is something wrong with your IBIS model. The DC end points
calculated from the I-V tables should match the V-T end points (logic
levels). If the error is within 2% you should get a warning, otherwise
an error. The difference you mention is very big.
The DC end points are calculated from the I-V tables (therefore you
don't see the end points of the V-T table). The I-V tables are derived
by sweeping a voltage at the output and measuring the resulting current.
By applying a certain load the voltages from the logic high and low
level are calculated from the pull-up and pull-down curve (and of course
they should be near the waveform end point voltages). The V-T data is
used to describe the transition between the logic levels calculated from
the I-V data.
I would suggest that you contact Cypress to ask if this model is OK.
With kind regards,
Ir. Erik van der Ven
Room DB1032
Business Line Networking Infrastructure
Philips Semiconductors BV
Gerstweg 2
6534 AE Nijmegen
The Netherlands
Phone: +31-24-3534334
KMuthulakshmi@scmmicro.co.in
Sent by:
owner-ibis-users@eda.org
07/28/03 05:32 AM
To: ibis-users@eda.org
cc: (bcc: Erik van der Ven/NYM/SC/PHILIPS)
Subject: [IBIS-Users] IBIS model Error
Classification:
Hi All,
I need IBIS expert's advice on the following.
I get the following warning when checking the IBIS model.
Warning - Model bp_usb_hs: The [Rising Waveform]
with [R_fixture]=45 Ohms and [V_fixture]=0V
has TYP column DC endpoints of 0.00V and 0.38v, but
an equivalent load applied to the model's I-V tables yields
different voltages ( 1.14V and 1.06V),
a difference of 99.99% and 64.28%, respectively.
Warning - Model bp_usb_hs: The [Falling Waveform]
with [R_fixture]=45 Ohms and [V_fixture]=0V
has TYP column DC endpoints of 0.00V and 0.38v, but
an equivalent load applied to the model's I-V tables yields
different voltages ( 1.14V and 1.06V),
a difference of 99.99% and 64.28%, respectively.
Warning - Model bp_usb_hs: The [Rising Waveform]
with [R_fixture]=45 Ohms and [V_fixture_min]=0V
has MIN column DC endpoints of 0.00V and 0.37v, but
an equivalent load applied to the model's I-V tables yields
different voltages ( 1.09V and 0.93V),
a difference of 99.99% and 60.23%, respectively.
Warning - Model bp_usb_hs: The [Falling Waveform]
with [R_fixture]=45 Ohms and [V_fixture_min]=0V
has MIN column DC endpoints of 0.00V and 0.37v, but
an equivalent load applied to the model's I-V tables yields
different voltages ( 1.09V and 0.93V),
a difference of 99.99% and 60.23%, respectively.
Warning - Model bp_usb_hs: The [Rising Waveform]
with [R_fixture]=45 Ohms and [V_fixture_max]=0V
has MAX column DC endpoints of 0.00V and 0.39v, but
an equivalent load applied to the model's I-V tables yields
different voltages ( 1.77V and 1.83V),
a difference of 100.00% and 78.72%, respectively.
Warning - Model bp_usb_hs: The [Falling Waveform]
with [R_fixture]=45 Ohms and [V_fixture_max]=0V
has MAX column DC endpoints of 0.00V and 0.38v, but
an equivalent load applied to the model's I-V tables yields
different voltages ( 1.77V and 1.83V),
a difference of 100.00% and 79.26%, respectively.
Please tell me the impact of this warning in simulation. I use XTK for
the simulation. Eventhough the rise and fall VT curve values range from
0V to 0.38V in the IBIS model, I get 1.04V to 1.14V wave form. How is
this related with this. I am using Cypress "CY7C65640" hub controller's
IBIS model.
Awaiting your earliest reply.
Note: One IBIS parser gives the above warnings and another parser gives
them as Errors.
I do not know whether files can be attached with this mail. If it
is OK, I can send the IBIS model.
thanks & regards
K.Muthu Lakshmi (KML)
SCM Microsystems (India) Pvt. Ltd.
email: KMuthulakshmi@scmmicro.co.in
Web: www.scmmicro.com
|------------------------------------------------------------------
|For help or to subscribe/unsubscribe, email majordomo@eda.org
|with just the appropriate command message(s) in the body:
|
| help
| subscribe ibis <optional e-mail address, if different>
| subscribe ibis-users <optional e-mail address, if different>
| unsubscribe ibis <optional e-mail address, if different>
| unsubscribe ibis-users <optional e-mail address, if different>
|