[IBIS-Users] Capacitance and transition time

From: Michael Sachtjen <walldrug1316mi_at_.....>
Date: Mon Jan 30 2006 - 11:23:46 PST
A coworker wants to simulate what affect connecting
different capacitors to the output pin of a device
would have on its transtion time.  He doesn't have
access to spice models and he asked me if he could use
IBIS models.  I told him that since the models are
characterized under a given load, changing that load
in simulation may not give him very accurate results. 
Was I correct, or will the simulator use the values of
the IV curves and test fixture to accurately skew the
rise and fall times specified in the VT curves?