RE: [IBIS-Users] Ground Clamp Reference

From: Lynne D. Green <lgreen22_at_.....>
Date: Wed Oct 18 2006 - 10:25:04 PDT
Sorry my answer was incomplete.

The range stays the same for all 3 corners: TYP -Vcc  to TYP 2*Vcc.

- Lynne

-----Original Message-----
From: NG,MEI-YEE [mailto:mei-yee.ng@avagotech.com] 
Sent: Tuesday, October 17, 2006 10:59 PM
To: Lynne D. Green; ibis-users@eda.org; ibis-users@eda.org; Ambrish Varma;
Mirmak, Michael
Subject: RE: [IBIS-Users] Ground Clamp Reference

Hi Lynne,

I understand that the range -Vcc to Vcc is the IBIS standard for Ground
Clamp curve, however, does the range change according to the min and max
simulation? For example, in min, my Vcc will be lower hence, the range -Vcc
to Vcc will be different from the range for typical simulation, is that
right? Same case for max, my Vcc will be higher, so does my simulation range
change according to the max Vcc as well?

Thanks.

Best regards,
Mei Yee

-----Original Message-----
From: Lynne D. Green [mailto:lgreen22@mindspring.com]
Sent: Wednesday, October 18, 2006 1:51 PM
To: NG,MEI-YEE; ibis-users@eda.org; ibis-users@eda.org; 'Ambrish Varma';
'Mirmak, Michael'
Subject: RE: [IBIS-Users] Ground Clamp Reference

Hello, Mei Yee,
 
Yes, this is standard for all of the I-V tables.  It is highly recommended
that all I-V tables should go from -Vcc to 2*Vcc in the completed IBIS
model.
 
More information can be found in the IBIS Cookbook.
http://www.vhdl.org/pub/ibis/cookbook/cookbook-v4.pdf
 
When you have completed a model, please feel free to send it to the IBIS
Model Review Committee.
http://www.eigroup.org/ibis/support.htm
 
Best regards,
Lynne
 
 
"IBIS training when you need it, where you need it."
 
Dr. Lynne Green
Green Streak Programs
http://www.greenstreakprograms.com
425-788-0412
lgreen22@mindspring.com
 

 

________________________________

	From: owner-ibis-users@eda.org [mailto:owner-ibis-users@eda.org] On
Behalf Of NG,MEI-YEE
	Sent: Tuesday, October 17, 2006 8:44 PM
	To: ibis-users@eda.org; ibis-users@eda.org; Ambrish Varma; Mirmak,
Michael
	Subject: [IBIS-Users] Ground Clamp Reference
	
	

	Hi all,

	 

	I used s2ibis3 to simulate my Input pad and I realized that the
sweep range for Ground Clamp curves are from -Vcc to Vcc, where Vcc is the
the value for typical. However, this range remains the same figure for ALL
corners i.e. fast, slow and typical. This means that if my Vcc is 3V, the
sweep range for all the corners is -3 to 3V, regardless of my Vcc at various
corners.

	 

	Is this the standard for Ground clamp? I tried using the keyword
[GND clamp reference] 2.7 3 3.3 but the range still remains -3 to 3V.

	 

	Kindly advice.

	 

	Thank you.

	 

	Best regards, 

	Mei Yee





--------------------------------------------------------------------
|For help or to subscribe/unsubscribe, e-mail majordomo@eda-stds.org
|with the appropriate command message(s) in the body:
|
|  help
|  subscribe   ibis       <optional e-mail address, if different>
|  subscribe   ibis-users <optional e-mail address, if different>
|  unsubscribe ibis       <optional e-mail address, if different>
|  unsubscribe ibis-users <optional e-mail address, if different>
|
|or e-mail a request to ibis-request@eda-stds.org.
|
|IBIS reflector archives exist under:
|
|  http://www.eda-stds.org/pub/ibis/email_archive/ Recent
|  http://www.eda-stds.org/pub/ibis/users_archive/ Recent
|  http://www.eda-stds.org/pub/ibis/email/         E-mail since 1993
Received on Wed Oct 18 10:25:16 2006

This archive was generated by hypermail 2.1.8 : Wed Oct 18 2006 - 10:25:46 PDT