[IBIS-Users] V-T different durations

From: Fabio BRINA <fabio.brina@st.com>
Date: Fri Jul 08 2011 - 07:23:34 PDT

Hello experts,

  a simply question (I suppose!) :

   Can I have different durations for the four V-T waveforms ?

   Till today I generated Rising0, Rising1, Falling0, Falling0 curves
    using the same durations, but Can I have the following situations:
    Rising0 --> 12 ns duration
    Rising1 --> 10ns duration
   Falling0 --> 8ns duration
    Falling1 --> 11ns duration

   Standard does not preclude it, but can cause problems to user?
 Thank you in advance.