Hi IBIS Experts, A quick help! When do I get this ERROR message fron ibis parser (ibischk3)? The [Rising Waveform] with [R_fixture]=50 Ohms and [V_fixture_min]=1.71V has MIN column DC endpoints of 0.86V and 1.59v, but an equivalent load applied to the model's I-V tables yields different voltages ( 0.82V and 1.49V), a difference of 6.87% and 14.93%, respectively. Any input would be of great help! Thanks, Anguraj -------------------------------------------------------------------- |For help or to subscribe/unsubscribe, e-mail majordomo@eda-stds.org |with the appropriate command message(s) in the body: | | help | subscribe ibis <optional e-mail address, if different> | subscribe ibis-users <optional e-mail address, if different> | unsubscribe ibis <optional e-mail address, if different> | unsubscribe ibis-users <optional e-mail address, if different> | |or e-mail a request to ibis-request@eda-stds.org. | |IBIS reflector archives exist under: | | http://www.eda-stds.org/pub/ibis/email_archive/ Recent | http://www.eda-stds.org/pub/ibis/users_archive/ Recent | http://www.eda-stds.org/pub/ibis/email/ E-mail since 1993Received on Wed Oct 18 05:55:44 2006