To find out how to submit a bug to the IBIS Open Forum, please read the document bugform.txt.
| ID# | Title | Requester | Date Submitted |
Severity | Priority | Status | Date Closed |
Supported Version |
|---|---|---|---|---|---|---|---|---|
| 256 | Unsupported path separators allowed in file references | Arpad Muranyi, Siemens EDA | September 5, 2025 | MODERATE | MEDIUM | OPEN | ||
| 255 | Incorrectly harsh Warning about mixing C_comp and C_comp_* | Curtis Clark, Ansys, Inc. | June 26, 2025 | MODERATE | MEDIUM | OPEN | ||
| 254 | AMI Reserved Parameter Repeater_Type erroneously reported as missing | Arpad Muranyi, Siemens EDA | April 24, 2025 | MODERATE | LOW | OPEN | ||
| 253 | Non-comments allowed after [End Interconnect Model Set] keyword | Justin Butterfield, Chinmaya Patra, Bibhu Panda; Micron Technology | March 31, 2025 | MODERATE | MEDIUM | OPEN | ||
| 252 | Incorrect BCI Interpretation Invalidates All Tx Models | Michael Mirmak, Intel Corporation | March 17, 2025 | SEVERE | HIGH | OPEN | ||
| 251 | Missing Repeater_Type not seen through Model Selector | Arpad Muranyi, Siemens EDA | November 15, 2024 | SEVERE | HIGH | OPEN | ||
| 250 | Incorrect [Diff Pin] caution report | Michael Mirmak, Intel Corp. | July 1, 2024 | ANNOYING | LOW | OPEN | ||
| 249 | Memory leaks caused by algmod.c, ami.c and cmn.c | Michael Mirmak, Intel Corporation | March 28, 2024 | ANNOYING | LOW | OPEN | ||
| 248 | Crash Caused by iassert macro and abort() | Michael Mirmak, Intel Corporation | March 19, 2024 | FATAL | MEDIUM | OPEN | ||
| 247 | Changing BOOL from Type Enum to Int | Michael Mirmak, Intel Corporation | March 19, 2024 | ENHANCEMENT | LOW | OPEN | ||
| 246 | Clarification on Slash Characters and Parser Usage | Michael Mirmak, Intel Corporation | December 22, 2023 | MODERATE | MEDIUM | OPEN | ||
| 245 | Has Platform Issue Message in IBIS-AMI Checking Not Clear | Weston Beal, Siemens EDA | June 13, 2023 | MODERATE | LOW | CLOSED | December 8, 2023 | 7.2.1 |
| 244 | False IBIS Ver Compatibility Error for EMD and IBIS File Checking | Randy Wolff, Arpad Muranyi; Siemens EDA | June 14, 2023 | MODERATE | MEDIUM | CLOSED | December 8, 2023 | 7.2.1 |
| 243 | Remove Make File Warning Messages During Compilations | Graham Kus, MathWorks; Michael Schaeder, Zuken; Curtis Clark, Ansys; Bob Ross, Teraspeed Labs | May 30, 2023 | ANNOYING | LOW | CLOSED | December 8, 2023 | 7.2.1 |
| 242 | Change Caution to Error for Illegal NC as signal_type and Change Message | Randy Wolff, Siemens | May 28, 2023 | SEVERE | MEDIUM | CLOSED | December 8, 2023 | 7.2.1 |
| 241 | Remove or Revise EMD Warning for Legal signal_name, signal_type Combinations | Randy Wolff, Siemens | May 26, 2023 | SEVERE | MEDIUM | CLOSED | December 8, 2023 | 7.2.1 |
| 240 | Parser Crashes When [Interconnect Model Group] Name is Missing | Arpad Muranyi, Siemens EDA | March 3, 2023 | SEVERE | HIGH | CLOSED | April 21, 2023 | 7.2.0 |
| 239 | No Message for Unreferenced [Interconnect Model Set]s | Michael Mirmak, Intel Corp. | March 3, 2023 | ENHANCEMENT | LOW | CLOSED | December 8, 2023 | 7.2.1 |
| 238 | Interconnect Models with Duplicate pin_names Incorrectly Produce Errors | Michael Mirmak, Intel Corp. | October 14, 2022 | MODERATE | MEDIUM | CLOSED | November 18, 2022 | 7.1.1 |
| 237 | Incorrect Arguments Produce No Error or Incorrect Errors for Rx_Use_Clock_Input | Arpad Murany, Siemens EDA; Bob Ross, Teraspeed Labs | September 17, 2022 | SEVERE | HIGH | CLOSED | November 18, 2022 | 7.1.1 |
| 236 | File_IBIS-ISS Error Message if Last Terminal of [C Comp Model] is Buffer_I/O | Randy Wolff, Micron Technology; Bob Ross, Teraspeed Labs | August 17, 2022 | SEVERE | MEDIUM | CLOSED | November 18, 2022 | 7.1.1 |
| 235 | No Error in [C Comp Model] if Required C_comp_model_mode is Missing | Randy Wolff, Micron Technology; Bob Ross, Teraspeed Labs | August 17, 2022 | SEVERE | MEDIUM | CLOSED | November 18, 2022 | 7.1.1 |
| 234 | No Error Reported for File Referenced with Absolute Path | Arpad Muranyi, Siemens EDA; Mike LaBonte, Unaffiliated; Bob Ross, Teraspeed Labs | June 5, 2022 | SEVERE | MEDIUM | CLOSED | November 18, 2022 | 7.1.1 |
| 233 | Parser Hangs with [Model Spec] Subparamenters and without Corresponding [Model] Subparameters | John Angulo, Siemens AG | April 17, 2022 | MODERATE | MEDIUM | CLOSED | November 18, 2022 | 7.1.1 |
| 232 | Unexpected Errors with Absolute Links Using Embedded Source Code in [IBIS Ver] 7.0 or 7.1 | Yingxin Sun, Cadence Design Systems | April 17, 2022 | MODERATE | MEDIUM | CLOSED | November 18, 2022 | 7.1.1 |
| 231 | B6801 and E6801 for Memory Overflow Issued in Two Different Code Locations | Mike LaBonte, MathWorks | February 8, 2022 | ANNOYING | MEDIUM | CLOSED | November 18, 2022 | 7.1.1 |
| 230 | Bad Error Message with [Clock Pins] with [Model Selector], [Diff Pin] | Michael Mirmak, Intel Corp. | January 28, 2022 | SEVERE | HIGH | CLOSED | November 18, 2022 | 7.1.1 |
| 229 | Code Fix for PKG file Error whan Stored in a Universal Network Path | Mike LaBonte, MathWorks | 26 Jan 2022 | ANNOYING | LOW | CLOSED | November 18, 2022 | 7.1.1 |
| 228 | With EMD, Checking IBIS 2.0 Through IBIS 6.1 File to IBIS 7.0 Rules | Randy Wolff, Micron Technology; Arpad Muranyi, Siemens EDA | January 17, 2022 | ANNOYING | LOW | CLOSED | November 18, 2022 | 7.1.1 |
| 227 | Check Root Name of .ami File with Root Name of Executable Model | Michael Mirmak, Intel Corp. | November 30, 2021 | ENHANCEMENT | LOW | OPEN | ||
| 226 | No Error for Param Entry in [Interconnect Model] with File_TS | Atul Agarwal, Apt Software Avenues | October 22, 2021 | SEVERE | MEDIUM | CLOSED | December 18, 2021 | 7.1.0 |
| 225 | No Error for IBIS_AMI List_Tip Different Entries for Duplicate List Entries | Mike LaBonte, MathWorks | October 22, 2021 | MODERATE | LOW | CLOSED | November 18, 2022 | 7.1.1 |
| 224 | No Warning for [Interconnect Model] with all Pins as Aggressor_Only | Atul Agarwal, Apt Software Avenues | September 4, 2021 | SEVERE | MEDIUM | CLOSED | December 18, 2021 | 7.1.0 |
| 223 | No Error for Duplicate [End Interconnect Model Set] | Atul Agarwal, Apt Software Avenues | September 4, 2021 | SEVERE | MEDIUM | CLOSED | December 18, 2021 | 7.1.0 |
| 222 | No Errors for Space in [Interconnect Model Set] or [Interconnect Model] Names | Atul Agarwal, Apt Software Avenues | 15th Aug 2021 | SEVERE | HIGH | CLOSED | December 18, 2021 | 7.1.0 |
| 221 | No Error for Missing [Begin Board Description]s in EBD or Missing [Interconnect Model Set]s in IMS | Atul Agarwal, Apt Software Avenues | 15th Aug 2021 | MODERATE | HIGH | CLOSED | December 18, 2021 | 7.1.0 |
| 220 | No Error Reported for Duplicate [Interconnect Model Set] | Atul Agarwal, Apt Software Avenues | 15th Aug 2021 | SEVERE | HIGH | CLOSED | December 18, 2021 | 7.1.0 |
| 219 | Coding Error Due to Wrong Case in imsmdl.c | Curtis Clark, Ansys | August 16, 2021 | MODERATE | HIGH | CLOSED | December 18, 2021 | 7.1.0 |
| 218 | Missing "else" in "if else" Line in hdr.c Impacting IBIS Ver | Curtis Clark, Ansys; Bob Ross, Teraspeed Labs | July 27, 2021 | SEVERE | HIGH | CLOSED | December 18, 2021 | 7.1.0 |
| 217 | [Algorithmic Model] Failure to Recognize Subdirectories | Curtis Clark, Ansys; Bob Ross, Teraspeed Labs | July 15, 2021 | SEVERE | HIGH | CLOSED | December 18, 2021 | 7.1.0 |
| 216 | IBIS-AMI UI Floating Point and Integer Number Mismatch Issues | Michael Mirmak, Intel Corp. | April 15, 2021 | ANNOYING | LOW | NOT A BUG | April 23, 2021 | |
| 215 | Connecting IBIS and Interconnect Models to Touchstone | Mike LaBonte, SiSoft (MathWorks); Randy Wolff, Micron Technology; Bob Ross, Teraspeed Labs, Lance Wang, Zuken USA | March 9, 2021 | ENHANCEMENT | MEDIUM | CLOSED | December 18, 2021 | 7.1.0 |
| 214 | Connecting IBIS and Interconnect Models to IBIS-ISS | Mike LaBonte, SiSoft (MathWorks); Randy Wolff, Micron Technology; Bob Ross, Teraspeed Labs, Lance Wang, Zuken USA | November 25, 2020 | ENHANCEMENT | MEDIUM | CLOSED | December 18, 2021 | 7.1.0 |
| 213 | Unused_port_termination Not Correct for Interconnect Model File_TS | Arpad Muranyi, Mentor, a Siemens Business; Bob Ross, Teraspeed Labs | May 5, 2020 | SEVERE | HIGH | CLOSED | August 3, 2020 | 7.0.2 |
| 212 | Coding Error with Bit-wise Single '&' in imsmdl.c, Line 1371 | Radek Biernacki, Keysight Technologies; Bob Ross, Teraspeed Labs | May 2, 2020 | ANNOYING | LOW | CLOSED | August 3, 2020 | 7.0.2 |
| 211 | Extreme Currents in Clamp Tables Report Modification | Michael Mirmak, Intel Corp. | March 3, 2020 | ANNOYING | MEDIUM | CLOSED | August 3, 2020 | 7.0.2 |
| 210 | [Model Selector] within [Component] Scope Issue | Michael Mirmak, Intel Corp. | February 5, 2020 | ANNOYING | LOW | CLOSED | August 3, 2020 | 7.0.2 |
| 209 | Correct E5801 and E5803 Error Messages for bus_label Tests | Atul Agarwal, Adept Software Avenues | 15th Dec 2019 | MODERATE | MEDIUM | CLOSED | December 16, 2019 | 7.0.1 |
| 208 | Missing Code Pointer Increment Causes [Interconnect Model Set] Test Case to Hang | Arpad Muranyi; Mentor, a Siemens Business | November 25, 2019 | SEVERE | HIGH | CLOSED | December 16, 2019 | 7.0.1 |
| 207 | Submodel clamps should be included in V-T extraction | Randy Wolff, Micron Technology; Bob Ross, Teraspeed Labs | September 26, 2019 | ANNOYING | LOW | WILL NOT FIX | February 21, 2020 | 7.0.1 |
| 206 | No Message in [Series Switch Groups] for Missing On and Off function table group Entries | Arpad Muranyi, Mentor, a Siemens Business; Bob Ross, Teraspeed Labs | September 2, 2019 | MODERATE | MEDIUM | CLOSED | August 3, 2020 | 7.0.2 |
| 205 | Error Not Reported for IBIS-AMI with Illegal Usage Out and Format Corner | Atul Agarwal, Adept Software Avenues | 9th May, 2019 | SEVERE | HIGH | CLOSED | October 8, 2019 | 7.0.0 |
| 204 | Message for IBIS-AMI Rx_Receiver Sensitivity Negative Value | Mike LaBonte, SiSoft | 7 May 2019 | ANNOYING | LOW | CLOSED | August 3, 2020 | 7.0.2 |
| 203 | C_comp_* Tests for Input_* and Terminator Models | Lance Wang - Zuken USA | April 1, 2019 | ENHANCEMENT | LOW | CLOSED | August 3, 2020 | 7.0.2 |
| 202 | IBIS-AMI Crashes on Linux with GLIBC2.11 | Wei-hsing Huang, SPISim | October 6, 2018 | SEVERE | MEDIUM | WILL NOT FIX | June 5, 2020 | 7.0.2 |
| 201 | Add [Pullup], [Pulldown] Warning for Input and Terminator Model_types | Lance Wang, IO Methodology; Bob Ross, Teraspeed Labs | August 6, 2018 | ENHANCEMENT | LOW | CLOSED | December 21, 2018 | 6.1.5 |
| 200 | Change B0122 to E0122 Message for Subparameters after [End External Model] | Bob Ross, Teraspeed Labs | August 6, 2018 | ANNOYING | LOW | CLOSED | December 21, 2018 | 6.1.5 |
| 199 | Wrong [External Circuit] Message E0275 Reported After IBISCHK6.1.2 | Arpad Murany, a Siemens Business; Bob Ross, Teraspeed Labs | August 5, 2018 | SEVERE | HIGH | CLOSED | December 21, 2018 | 6.1.5 |
| 198 | Illegal Language IBIS-ISS Not Reported Below Version 6.0 Files | Bob Ross, Teraspeed Labs | August 5, 2018 | SEVERE | MEDIUM | CLOSED | December 21, 2018 | 6.1.5 |
| 197 | IBIS-AMI No Messages for Delta <= 0.0 or Step <= 0.0 | Lance Wang, IO Methodology; Mike LeBonte, SiSoft; Bob Ross, Teraspeed Labs | June 26, 2018 | ANNOYING | LOW | CLOSED | December 21, 2018 | 6.1.5 |
| 196 | No Error for D_to_A Polarity Entry for [IBIS Ver] 5.1 and Below | Arpad Muranyi, Mentor, a Siemens Business; Bob Ross, Teraspeed Labs | December 17, 2017 | MODERATE | MEDIUM | CLOSED | December 21, 2018 | 6.1.5 |
| 195 | No Error for Missing [End Node Declarations] | Arpad Muranyi, Mentor, a Siemens Business; Bob Ross, Teraspeed Labs | December 17, 2017 | MODERATE | MEDIUM | CLOSED | December 21, 2018 | 6.1.5 |
| 194 | Correct E0544 Message has TBD in Text | Michael Schaeder, Zuken; Mike LaBonte, SiSoft | December 5, 2017 | ANNOYING | LOW | CLOSED | December 21, 2018 | 6.1.5 |
| 193 | [Ramp] dV Caution Message with No I-V Tables and [External Model] | Michael Mirmak, Intel Corp. | August 29, 2017 | ANNOYING | LOW | CLOSED | December 21, 2018 | 6.1.5 |
| 192 | Clarify Diff Pin and Single-Ended Pin Caution Message for Same Model | Michael Mirmak, Intel Corp. | August 29, 2017 | ANNOYING | LOW | CLOSED | December 21, 2018 | 6.1.5 |
| 191 | Missing [Component] Keyword Causes Program Bug Message | Michael Mirmak, Intel Corp. | August 14, 2017 | ANNOYING | LOW | CLOSED | December 21, 2018 | 6.1.5 |
| 190 | Multi-lingual [External Model] Error Messages Cleanup | Ambrish Varma, Cadence Design Systems, Arpad Muranyi, Mentor, A Siemens Business; and Bob Ross, Teraspeed Labs | August 2, 2017 | MODERATE | LOW | CLOSED | December 21, 2018 | 6.1.5 |
| 189 | Crash When Model Selector Points to Non-Existent [Model] | Yingxin Sun, Cadence Design Systems and Bob Ross, Teraspeed Labs | March 21, 2017 | SEVERE | HIGH | CLOSED | June 28, 2017 | 6.1.4 |
| 188 | No Error Message for Empty Files | Bob Ross, Teraspeed Labs | March 21, 2017 | MODERATE | LOW | CLOSED | June 28, 1917 | 6.1.4 |
| 187 | IBIS-AMI Related Missing New Line for 64-Bit Operating System Reports | Mike LaBonte, Signal Integrity Software | March 21, 2017 | MODERATE | LOW | CLOSED | June 28, 2017 | 6.1.4 |
| 186 | IBIS-AMI with Linux Adds ./ with Filename; Windows: %1 Message | Mike LaBonte, Signal Integrity Software (SiSoft) | March 21, 2017 | ANNOYING | LOW | NOT A BUG | June 28, 2017 | 6.1.4 |
| 185 | IBISCHK6 Compiled for MacOS Reports Compiled with Linux, Checks as Linux | Mike LaBonte, Signal Integrity Software and David Banas eASIC | March 21, 2017 | MODERATE | MEDIUM | CLOSED | June 28, 2017 | 6.1.4 |
| 184 | No Error for AMI_Version 6.1 Reserved_Parameters Under Model_Specific Branch | Bob Ross, Teraspeed Labs | November 14, 2016 | MODERATE | MEDIUM | CLOSED | June 28, 2017 | 6.1.4 |
| 183 | IBIS-AMI Error Message Contradiction with (Usage Out) | Michael Mirmak, Intel Corp. | September 20, 2016 | ANNOYING | LOW | CLOSED | June 28, 2017 | 6.1.4 |
| 182 | No Error for [Algorithmic Model] Executable with Paths in File_Name | Michael Mirmak, Intel Corporation and Bob Ross, Teraspeed Labs | September 25, 2016 | ANNOYING | LOW | CLOSED | June 28, 2017 | 6.1.4 |
| 181 | IBIS-AMI Non-7-Bit ASCII Character Creates False Errors and Line Numbers | Michael Mirmak, Intel Corporation | September 20, 2016 | ANNOYING | MEDIUM | CLOSED | June 28, 2017 | 6.1.4 |
| 180 | Error with Legal List_Tip in Reserved_Parameters with Format List | Mike LaBonte, Signal Intergrity Software (SiSoft) | July 20, 2016 | MODERATE | MEDIUM | CLOSED | December 2, 2016 | 6.1.3 |
| 179 | DLL SO Checking and Functional Existence and Platform Information | Mike LaBonte, SiSoft; Bob Ross, Teraspeed Labs; Lance Wang, IO Methodology | June 9, 2016 | ENHANCEMENT | MEDIUM | CLOSED | December 2, 2016 | 6.1.3 |
| 178 | Error with Same Platform_Compiler_Bits for Rx and Tx of I/O* in IBIS-AMI | Michael Schaeder, Zuken; Bob Ross, Teraspeed Labs | May 31, 2016 | SEVERE | HIGH | CLOSED | December 2, 2016 | 6.1.3 |
| 177 | Empty [Node Declarations] Stops Parser Completion | Arpad Muranyi, Mentor Graphics; and Bob Ross, Teraspeed Labs | May 26, 2016 | SEVERE | MEDIUM | CLOSED | December 2, 2016 | 6.1.3 |
| 176 | [External Model] Error Not Issued for Ports List With Undeclared Port | Arpad Muranyi, Mentor Graphics; and Bob Ross, Teraspeed Labs | May 26, 2016 | MODERATE | MEDIUM | CLOSED | December 2, 2016 | 6.1.3 |
| 175 | Incorrect Model References Through [Model Selector] Not Reported | Walter Katz, SiSoft | April 4, 2016 | MODERATE | MEDIUM | CLOSED | December 2, 2016 | 6.1.3 |
| 174 | File Not Found Line Printed Under Some Operating Systems | Mike LaBonte, SiSoft and Bob Ross, Teraspeed Labs | March 15, 2016 | ANNOYING | LOW | CLOSED | December 2, 2016 | 6.1.3 |
| 173 | Invalid Package Matrix Checks for Wrapped Banded Matrices | Curtis Clark, ANSYS | January 15, 2016 | MODERATE | MEDIUM | CLOSED | February 23, 2016 | 6.1.2 |
| 172 | Incorrect Error Messages for Legal [Pin Mapping] Bus Label Connections | Bob Ross, Teraspeed Labs; Curtis Clark, ANSYS | January 5, 2016 | SEVERE | MEDIUM | CLOSED | February 23, 2016 | 6.1.2 |
| 171 | Below [IBIS Ver] 6.1, I/O [Model]s With [Algorithmic Model] Executable Fail | Mike LaBonte, Signal Integrity Software | December 17, 2015 | SEVERE | HIGH | CLOSED | January 8, 2016 | 6.1.1 |
| 170 | Compilation with Parse_SupressBanners() Causes Implicit AMI_Ver "5.0" Error | Michael Schaeder, Zuken | December 16, 2015 | MODERATE | LOW | CLOSED | January 11, 2016 | 6.1.1 |
| 169 | No Error for Package Model [Capacitance Matrix] Positive Off-Diagonals | Bob Ross, Teraspeed Labs | November 27, 2015 | MODERATE | MEDIUM | CLOSED | January 8, 2016 | 6.1.1 |
| 168 | Package Model [* Matrix] Precision Errors | Mike LaBonte, Signal Integrity Software | November 27, 2015 | SEVERE | HIGH | CLOSED | January 8, 2016 | 6.1.1 |
| 167 | Missing or Faulty Modulation "PAM4" Checks | Bob Ross, Teraspeed Labs | November 16, 2015 | MODERATE | MEDIUM | CLOSED | January 8, 2016 | 6.1.1 |
| 166 | No Error IBIS-AMI Executable Parameter_File Without .ami Extension | Bob Ross, Teraspeed Labs | November 15, 2015 | MODERATE | MEDIUM | CLOSED | January 8, 2016 | 6.1.1 |
| 165 | No Error for Executable line direction Mismatches under [Algorithmic Model] | Bob Ross, Teraspeed Labs | November 14, 2015 | MODERATE | MEDIUM | CLOSED | January 8, 2016 | 6.1.1 |
| 164 | Model_Specific (Usage Dep) Parameter Error Not Issued for AMI_Ver "6.0" | Bob Ross, Teraspeed Labs | November 14, 2015 | MODERATE | MEDIUM | CLOSED | January 8, 2016 | 6.1.1 |
| 163 | Improper Handling of [Alternate Package Models] | Atul Agarwal, Apt Software | Oct 16, 2015 | MODERATE | MEDIUM | CLOSED | January 8, 2016 | 6.1.1 |
| 162 | Ibischk6 Source Code Cleanup | Curtis Clark, ANSYS, Inc. | April 10, 2015 | ANNOYING | LOW | CLOSED | November 20, 2015 | 6.1.0 |
| 161 | Table and Format as Model_Specific Parameter Names Causes Errors | Mike LaBonte, SiSoft; Bob Ross, Teraspeed Labs | April 9, 2015 | MODERATE | LOW | CLOSED | November 20, 2015 | 6.1.0 |
| 160 | Eliminate Compile and Link Errors with Debug Enabler IBIS_PRINT | Curtis Clark, ANSYS, Inc. | March 11, 2015 | ANNOYING | LOW | CLOSED | November 20, 2015 | 6.1.0 |
| 159 | Incorrect String Arguments Accepted for IBIS-AMI Parameters | Mike LaBonte, SiSoft | March 10, 2015 | MODERATE | HIGH | CLOSED | November 20, 2015 | 6.1.0 |
| 158 | Disable Undocumented -etc Flag for Added Multi-Lingual Checks | Mike LaBonte, SiSoft, Bob Ross, Teraspeed Labs | September 16, 2014 | ANNOYING | LOW | CLOSED | November 3, 2014 | 6.0.1 |
| 157 | E5118 When Repeater Input Models Have Multiple Executable Lines | Mike LaBonte, SiSoft | August 25, 2014 | SEVERE | HIGH | CLOSED | November 3, 2014 | 6.0.1 |
| 156 | Rename string.h and string.c to stringlist.h and stringlist.c | Michael Schaeder, Zuken, Bob Ross, Teraspeed Consulting Group | May 15, 2014 | ENHANCEMENT | MEDIUM | CLOSED | June 20, 2014 | 6.0.0 |
| 155 | Warning Message for Vinh < Vinl | Curtis Clark, ANSYS, Inc. | May 5, 2014 | ENHANCEMENT | LOW | CLOSED | November 20, 2015 | 6.1.0 |
| 154 | Suppress Repeated AMI File Checking | Mike LaBonte, SiSoft; Bob Ross, Teraspeed Consulting Group | April 23, 2014 | ENHANCEMENT | LOW | CLOSED | June 20, 2014 | 6.0.0 |
| 153 | Add AMI_Version to Checking Message for AMI Files | Mike LaBonte, SiSoft; Bob Ross, Teraspeed Consulting Group | April 23, 2014 | ENHANCEMENT | LOW | CLOSED | June 20, 2014 | 6.0.0 |
| 152 | Null Root Name for AMI file Should Generate Error Message | Bob Ross, Teraspeed Consulting Group | April 16, 2014 | ANNOYING | LOW | CLOSED | June 20, 2014 | 6.0.0 |
| 151 | Checking of (-) Diagonal Entries in RLC [Package Model] Matrices | Randy Wolff, Micron Technology, Inc. | 02/21/2014 | ENHANCEMENT | LOW | CLOSED | November 20, 2015 | 6.1.0 |
| 150 | Ambiguous Directionality Possible with [Algorithmic Model] | Michael Mirmak, Intel Corp. | Feb. 7, 2014 | ENHANCEMENT | LOW | NOT A BUG | ||
| 149 | Fatal Hang by EBD Referencing Longer Filename IBIS Files | Michael Schaeder, Zuken, Bob Ross, Teraspeed Consulting Group | January 24, 2014 | SEVERE | MEDIUM | CLOSED | June 20, 2014 | 6.0.0 |
| 148 | Compilation warning related to tempnam | Michael Mirmak, Intel Corp. | 10/18/13 | ANNOYING | LOW | CLOSED | June 20, 2014 | 6.0.0 |
| 147 | Fatal Assertion Failure with AMI Indented Comment Line | Mike LaBonte, Signal Integrity Software | 20 Sep 2013 | SEVERE | MEDIUM | CLOSED | June 20, 2014 | 6.0.0 |
| 146 | Mixing AMI Versions "5.0" and "5.1" Reset Issue | Bob Ross, Teraspeed Consulting Group, Arpad Muranyi, Mentor Graphics | May 4, 2013 | MODERATE | HIGH | CLOSED | July 9, 2013 | 5.1.4 |
| 145 | Bad Pointer in testcase.c File | Yingxin Sun, Cadence Design Systems. | April 5, 2013 | ANNOYING | LOW | CLOSED | July 9, 2013 | 5.1.4 |
| 144 | Wrong Keyword Position BUG B0122 Message Should be ERROR E0122 Message | Mike LaBonte, Signal Integrity Software (SiSoft) | 22 Jan 2013 | ANNOYING | LOW | CLOSED | March 20, 2013 | 5.1.3 |
| 143 | Missing and Misspelled Argument Names in ccomp.c | Curtis Clark, ANSYS, Inc. | January 14, 2013 | MODERATE | LOW | CLOSED | March 20, 2013 | 5.1.3 |
| 142 | Mistake in TYPEDEF ENUM SMSPEC_SUB in smspec.h | Yingxin Sun, Cadence Design Systems. | January 14, 2013 | MODERATE | LOW | CLOSED | March 20, 2013 | 5.1.3 |
| 141 | Wrong AMI_INTEGER_MIN Value in ami.h | Curtis Clark, ANSYS, Inc. | January 14, 2013 | MODERATE | LOW | CLOSED | March 20, 2013 | 5.1.3 |
| 140 | Unexpected Non-Monotonic Warning Messages for Combined I-V Tables | Joy Li and Yingxin Sun, Cadence Design Systems | 29 Nov 2012 | ANNOYING | MEDIUM | CLOSED | March 20, 2013 | 5.1.3 |
| 139 | Incorrect [Ramp] dV Caution Message for 3-state_ECL Models | Curtis Clark, ANSYS, Inc. | November 27, 2012 | MODERATE | MEDIUM | CLOSED | March 20, 2013 | 5.1.3 |
| 138 | Parser Does Not Detect 0 or 0.0 Default Values as List Members | Walter Katz, Signal Integrity Software; Bob Ross, Teraspeed Consulting Group; and Michael Mirmak, Intel | September 28, 2012 | SEVERE | HIGH | CLOSED | October 5, 2012 | 5.1.2 |
| 137 | Warnings Generated by Compilation of IBISCHK5 Version 5.1.0 Code | Michael Mirmak, Intel | September 26, 2012 | ANNOYING | LOW | CLOSED | October 5, 2012 | 5.1.1 |
| 136 | Old EBD Test Generates Internal Errors | Atul P Agarwal, Apt Software Avenues | 21st Sept, 2012 | MODERATE | MEDIUM | CLOSED | September 26, 2012 | 5.1.0 |
| 135 | Ill-formed Parameter Not Detected in Several Locations | Michael Mirmak, Intel and Bob Ross, Teraspeed Consulting Group | September 18, 2012 | MODERATE | HIGH | CLOSED | September 26, 2012 | 5.1.0 |
| 134 | Incorrect Caution Messages for Open_sink dV | Eckhard Lenski, Nokia Siemens Networks and Bob Ross, Teraspeed Consulting Group | September 11, 2012 | MODERATE | MEDIUM | CLOSED | September 26, 2012 | 5.1.0 |
| 133 | IBIS-AMI Program Bug or Missing Error with Spurious Words | Todd Westerhoff, SiSoft and Bob Ross, Teraspeed Consulting Group | March 26, 2012 | MODERATE | HIGH | CLOSED | September 26, 2012 | 5.1.0 |
| 132 | [Model Selector] under [Notes] Causes Program Close | Jinhui Zhang, Cadence Design Systems and Bob Ross, Teraspeed Consulting Group | February 25, 2012 | SEVERE | MEDIUM | CLOSED | September 26, 2012 | 5.1.0 |
| 131 | Error for Rx_Clock_PDF Format Table | Mike LaBonte, Signal Integrity Software | 26 Jan 2012 | MODERATE | MEDIUM | CLOSED | September 26, 2012 | 5.1.0 |
| 130 | Program Closure with Case Sensitive Errors in Ramp Subparameters | Lance Wang, IO Methodology, Randy Wolff, Micron Technology, Bob Ross, Teraspeed Consulting Group | October 14, 2011 | SEVERE | HIGH | CLOSED | October 28, 2011 | 5.0.7 |
| 129 | Identical [Composite Current] points erroneously required | Lance Wang, I/O Methodology | July 21, 2011 | MODERATE | MEDIUM | CLOSED | October 7,2011 | 5.0.7 |
| 128 | Repetition of Reserved Parameters and Model_Specific Sections Not Checked | Bob Ross, Teraspeed Consulting Group | March 29, 2011 | ANNOYING | MEDIUM | CLOSED | September 26, 2012 | 5.1.0 |
| 127 | IBIS-AMI Fatal Error with Root Parameter Spurious Text | Bob Ross, Teraspeed Consulting Group | March 13, 2011 | SEVERE | HIGH | CLOSED | September 26, 2012 | 5.1.0 |
| 126 | Illegal Text After IBIS-AMI Parameters Not Reported | Walter Katz, SiSoft and Bob Ross, Teraspeed Consulting Group | March 9, 2011 | MODERATE | HIGH | CLOSED | September 26, 2012 | 5.1.0 |
| 125 | Missing Basic Checks on .ami Files | Walter Katz, SiSoft and Bob Ross, Teraspeed Consulting Group | January 6, 2011 | MODERATE | HIGH | CLOSED | September 26, 2012 | 5.1.0 |
| 124 | Erroneous Whitespace Requirement in .ami Files | Curtis Clark, Ansys, Inc. | January 4, 2011 | MODERATE | MEDIUM | CLOSED | September 26, 2012 | 5.1.0 |
| 123 | Wrong Cautions for [Ramp] dV | PRABHAT RANJAN, STMicroelectronics Pvt Ltd | December 14, 2010 | MODERATE | MEDIUM | CLOSED | March 17, 2011 | 5.0.6 |
| 122 | [Model Spec] Vref and Rref Values Ignored in Timing Load Check | Sergey Nikonchuk, Andrey Babintsev - Freescale Semicondictor Inc. | October 9, 2010 | MODERATE | MEDIUM | CLOSED | October 7, 2011 | 5.0.7 |
| 121 | Broken Missing [Component] Test | Atul Agarwal, Adept Software Avenues | September 1, 2010 | SEVERE | MEDIUM | CLOSED | November 5, 2010 | 5.0.4 |
| 120 | Unusued [Model Selector] Caution | Bob Ross, Teraspeed Consulting Group | July 27, 2010 | ENHANCEMENT | LOW | NOT A BUG | ||
| 119 | Waveform Test Missing Results with Version 4.2.1 and Beyond | Bob Ross, Teraspeed Consulting Group | July 5, 2010 | SEVERE | MEDIUM | CLOSED | November 5, 2010 | 5.0.4 |
| 118 | Vmeas Check with Version 4.2.1 and Beyond Failure | Bob Ross, Teraspeed Consulting Group | July 5, 2010 | SEVERE | MEDIUM | CLOSED | November 5, 2010 | 5.0.4 |
| 117 | Debug Error with Missing Pin Numbers and Other Conditions | Bob Ross, Teraspeed Consulting Group and Arpad Muranyi, Mentor Graphics | June 3, 2010 | SEVERE | MEDIUM | CLOSED | February 13, 2011 | 5.0.5 |
| 116 | [ISSO_PU] and [ISSO_PD] Mismatch Checks Insufficent Resolution | Sergey Nikonchuk, Andrey Babintsev - Freescale Semicondictor Inc. | April 22, 2010 | SEVERE | MEDIUM | CLOSED | March 17, 2011 | 5.0.6 |
| 115 | [ISSO_PU] and [ISSO_PD] Mismatch Checks Not Done for Typ Column | Sergey Nikonchuk, Andrey Babintsev - Freescale Semicondictor Inc. | April 22, 2010 | SEVERE | HIGH | CLOSED | February 13, 2011 | 5.0.5 |
| 114 | V4.X Name and Column Lengths for [Submodel] and [Model Selector] | Eckhard Lenski, Nokia Siemens Networks and Bob Ross, Teraspeed | February 10, 2010 | SEVERE | HIGH | CLOSED | November 5, 2010 | 5.0.4 |
| 113 | Segmentation Error in V5.0.2 Compilation | Michael Mirmak, Intel and Bob Ross, Teraspeed Consulting Group | February 10, 2010 | SEVERE | HIGH | CLOSED | February 11, 2010 | 5.0.3 |
| 112 | Wrong Message for AMI File Without Extension | Bob Ross, Teraspeed consulting Group | January 31, 2010 | ANNOYING | MEDIUM | NOT A BUG | November 5, 2010 | |
| 111 | CRLF Should be Supported within AMI Syntax | Bob Ross, Teraspeed Consulting Group | January 8, 2010 | MODERATE | HIGH | CLOSED | January 30, 2010 | 5.0.2 |
| 110 | Wrong D_overshoot_ampl_* Subparameter Spelling | PRABHAT RANJAN, STMicroelectronics Pvt Ltd | December 18, 2009 | SEVERE | HIGH | CLOSED | January 30, 2010 | 5.0.2 |
| 109 | AMI Model Type String Not Supported | Todd Westerhoff, SiSoft | Dec 8, 2009 | SEVERE | HIGH | CLOSED | January 30, 2010 | 5.0.2 |
| 108 | IBIS 4.2/5.0 Message Differences for Multi-lingual Models | Shangli Wu, Cadence and Bob Ross, Teraspeed Consulting Group | December 2, 2009 | SEVERE | HIGH | CLOSED | December 11, 2009 | 5.0.1 |
| 107 | Checking for [Ramp] dV_r and dV_f | Mike LaBonte, Cisco Systems? | 30 October 2009 | ENHANCEMENT | LOW | CLOSED | November 5, 2010 | 5.0.4 |
| 106 | S_overshoot_* Invalid for Some Model_types | Bob Ross, Teraspeed Consulting Group | September 7, 2009 | ANNOYING | MEDIUM | CLOSED | November 5, 2010 | 5.0.4 |
| 105 | Incorrect Error for [Model Selector] Description Field Length | PRABHAT RANJAN, ST Microelectronics | August 3, 2009 | MODERATE | MEDIUM | CLOSED | November 5, 2010 | 5.0.4 |
| 104 | Error With Same [Test Load] Name Under Different [Model] | Tim Coyle, Signal Consulting Group LLC | 7/7/09 | ANNOYING | LOW | NOT A BUG | October 7, 2011 | 5.0.6 |
| 103 | Driver Schedule Delay Value Tests | Arpad Muranyi, Mentor Corporation | July 7, 2009 | MODERATE | MEDIUM | CLOSED | November 5, 2010 | 5.0.4 |
| 102 | Adding Numbers to Errors, Warnings and Other Messages | Bob Ross, Teraspeed Consulting Group | June 1, 2009 | ENHANCEMENT | MEDIUM | CLOSED | October 29, 2009 | 5.0.0 |
| 101 | No Warning for Unused [Model Selector] Name | Prabhat Ranjan, STMicroelectronics | October 10, 2008 | ENHANCEMENT | LOW | CLOSED | November 5, 2010 | 5.0.4 |
| 100 | Incorrect Ordering of [Circuit Call] | Michael Mirmak, Intel Corp. | January 21, 2008 | ANNOYING | LOW | NOT A BUG | Feb. 5, 2008 | n/a |
| 99 | Misleading Text in [Node Declarations] Error Message | Arpad Muranyi, Mentor Graphics | January 14, 2008 | ANNOYING | LOW | CLOSED | November 5, 2010 | 5.0.4 |
| 98 | Code Changes for Robustness | Bob Ross Teraspeed Consulting Group and Michael Schaeder, Zuken | June 14, 2007 | ANNOYING | LOW | CLOSED | July 17, 2007 | 4.2.2 |
| 97 | Reduction in Notes+Warning versus Earlier Warning Count | Bob Ross Teraspeed Consulting Group | May 26, 2007 | ANNOYING | LOW | CLOSED | July 17, 2007 | 4.2.2 |
| 96 | Put Line Numbers in Note Text | Bob Ross Teraspeed Consulting Group | May 26, 2007 | MODERATE | LOW | CLOSED | July 17, 2007 | 4.2.2 |
| 95 | Incorrect Differential Pin Assignment Warning | Bob Ross, Teraspeed Consulting Group | April 26, 2007 | MODERATE | HIGH | CLOSED | July 17, 2007 | 4.2.2 |
| 94 | Non-monotonic Warnings for Combined Tables in all Versions | Mike LaBonte Cisco, and IBIS Quality Committee Members, Kim Helliwell LSI Logic, Eckhard Lenski Siemens, Bob Ross Teraspeed, | 31 Mar 2006 | ENHANCEMENT | LOW | CLOSED | March 31, 2007 | 4.2.1 |
| 93 | Single-ended Threshold Warnings for Differential Models | Randy Wolff, Micron Technology, Inc. | 03/09/2006 | SEVERE | MEDIUM | CLOSED | March 31, 2007 | 4.2.1 |
| 92 | Non-monotonic Warnings for [Submodel] Dynamic_clamp | Randy Wolff and Pavani Jella, Micron Technology, Inc. | 01/09/2006 | MODERATE | MEDIUM | CLOSED | March 31, 2007 | 4.2.1 |
| 91 | Non-zero Currents in Unused Open_* Model I-V Tables | John Angulo, Mentor Graphics Corp. | 10/26/05 | ENHANCEMENT | LOW | CLOSED | March 31, 2007 | 4.2.1 |
| 90 | Parser Permits Vmeas Not Between Vinh and Vinl | Bob Haller SiSoft, and IBIS Quality Committee Members, Eckhard Lenski Siemens, Mike LaBonte Cisco Systems, Bob Ross Teraspeed, Kim Helliwell LSI Logic | August 2, 2005 | ENHANCEMENT | LOW | CLOSED | March 31, 2007 | 4.2.1 |
| 89 | Compiled Source Causes EBD Error from Missing DEFINES | Shangli Wu (Cadence) | 7/19/2005 | MODERATE | MEDIUM | CLOSED | July 1, 2006 | 4.2.0 |
| 88 | Version GLIBC_2.3 Not Found in ibischk4 Version 4.1.1 | Christophe ROBICHON (ATMEL) | July 6, 2005 | MODERATE | MEDIUM | CLOSED | July 1, 2006 | 4.2.0 |
| 87 | Re-enter BUG82 Fix | Bob Ross, Teraspeed Consulting Group, Doran David, Toshiba | March 23, 2005 | MODERATE | HIGH | CLOSED | April 10, 2005 | 4.1.1 |
| 86 | Inappropriate Compilation Options | Michael Mirmak, Intel Corp. | May 6, 2004 | ANNOYING | LOW | CLOSED | July 1, 2006 | 4.2.0 |
| 85 | Incorrect Header in wvfm.h | Michael Mirmak, Intel Corp. | May 6, 2004 | ANNOYING | LOW | CLOSED | April 10, 2005 | 4.1.1 |
| 84 | Parser Crashes with No Arguments to [Pin Numbers] | Michael Mirmak, Intel Corp. | March 26, 2004 | MODERATE | MEDIUM | CLOSED | March 31, 2007 | 4.2.1 |
| 83 | Parser Permits Pin-only [Pin Numbers] Entries | Michael Mirmak, Intel Corp. | March 26, 2004 | ANNOYING | LOW | CLOSED | March 31, 2007 | 4.2.1 |
| 82 | Waveform Mismatch Error for Open Source/Drain | Bob Haller, Signal Integrity Software, Formatted by John Angulo, Mentor Graphics Corp. | January 23, 2004 | MODERATE | MEDIUM | CLOSED | April 15, 2004 | 4.0.2 |
| 81 | Waveform Mismatch Error with Small Voltage Step | Randon K Richards and Arpad Muranyi, Intel Corp., Bob Haller, Signal Integrity Software, Formatted by Bob Ross, Teraspeed Consulting Group | November 5, 2003 | ANNOYING | LOW | CLOSED | December 1, 2003 | 4.0 (beta), 4.0.1 |
| 80 | Error Message with [Model Selector] Placement | John Angulo, Mentor Graphics Corp. | 26 June 2003 | ANNOYING | LOW | WILL NOT FIX | October 4, 2004 | |
| 79 | Program Bug in [Submodel Spec] Array | Matthew Flora, Mentor Graphics Corp. | 7 Feb 2003 | SEVERE | MEDIUM | CLOSED | July 15, 2003 | 4.0 (beta) |
| 78 | Clamp Current Double Counting Test | Roy Leventhal, Leventhal Design & Communications | 11/18/02 | ENHANCEMENT | LOW | WILL NOT FIX | March 7, 2003 | |
| 77 | Test for Series* Models in [Pin] Error | Lance Wang, Cadence Design Systems Inc. | 10/29/2002 | MODERATE | MEDIUM | CLOSED | July 15, 2003 | 4.0 (beta) |
| 76 | External Package Under Win32 Requires Writeable Root | Alexander Loehr, Zuken | Oct 17 2002 | MODERATE | LOW | CLOSED | July 15, 2003 | 4.0 (beta) |
| 75 | Successive EBD Checking Crashes Automated Checker | Lynne Green, Cadence Design Systems, (Modified by Bob Ross, Mentor Graphics) | 29 August 2002 | ANNOYING | LOW | CLOSED* | July 15, 2003 | 4.0 (beta) |
| 74 | Missing Timing Test Load Warning Messages | Greg Edlund, IBM | 26 Aug 2002 | ANNOYING | MEDIUM | CLOSED | July 15, 2003 | 4.0 (beta) |
| 73 | Extreme Non-Monotonic I-V Table Fails End-Point Test | Arpad Muranyi, Intel Corp. | August 27, 2002 | ANNOYING | LOW | CLOSED | December 1, 2003 | 4.0 (beta), 4.0.1 |
| 72 | Tab Warning Message Promotion | Lynne Green, Cadence Design Systems | 12 August 2002 | ANNOYING | LOW | CLOSED | July 15, 2003 | 4.0 (beta) |
| 71 | Monotonic Checking for Combined I-V Tables | Bob Haller SiSoft | 8 Aug 2002 | ENHANCEMENT | LOW | CLOSED | July 15, 2003 | 4.0 (beta) |
| 70 | [Model Selector] Fails for [Series Pin Mapping] Models | Moshiul Haque, Texas Instruments | 23 Apr 2002 | MODERATE | MEDIUM | CLOSED | July 15, 2003 | 4.0 (beta) |
| 69 | Error in EBD Path with Power Pin | Matthew Flora, Innoveda, Inc. | 23 Apr 2002 | MODERATE | LOW | CLOSED | July 15, 2003 | 4.0 (beta) |
| 68 | False Messages with Repeated Voltages | Michael Mirmak, Intel Corp. | April 8, 2002 | ANNOYING | LOW | CLOSED | December 1, 2003 | 4.0 (beta), 4.0.1 |
| 67 | Phantom Warnings Use Wrong Line Numbers and then Disappear | Matthew Flora, Innoveda, Inc. | 5 Feb 2002 | ANNOYING | LOW | CLOSED | July 12, 2002 | 3.2.9 |
| 66 | Improve Truncation of Long File Name | Jim Bell, SiQual Inc. | 1/17/02 | ANNOYING | LOW | CLOSED | July 12, 2002 | 3.2.9 |
| 65 | Change P/NMOSFET Series Element Error to Warning | Bob Ross, Mentor Graphics (from Todd Andersen, Philips) | 12/5/2001 | MODERATE | MEDIUM | CLOSED | July 12, 2002 | 3.2.9 |
| 64 | Error with Four [Driver Schedule] Entries | Arpad Muranyi, Intel Corp. | 12/04/2001 | MODERATE | HIGH | CLOSED | July 12, 2002 | 3.2.9 |
| 63 | Some BUG47 Reported Waveform Percentages Wrong | Bob Ross, Mentor Graphics | 11/01/01 | ANNOYING | MEDIUM | CLOSED | July 12, 2002 | 3.2.9 |
| 62 | Not All Non-Montonic Points Reported | Tracy Sopchak for Cameron Seitz - Cadence Design Systems | 10/16/01 | ANNOYING | LOW | WILL NOT FIX | ||
| 61 | Parser Fails to Flag Missing [Series Switch Groups] Table | Jim Bell, SiQual Corp | 10/12/01 | MODERATE | MEDIUM | CLOSED | July 12, 2002 | 3.2.9 |
| 60 | Incorrect Series Function Table Order Dependency | Bob Ross, Mentor Graphics | August 23, 2001 | MODERATE | MEDIUM | CLOSED | July 12, 2002 | 3.2.9 |
| 59 | Crash with Decimal Points for [Package] Subparameters | Michael Mirmak, Intel Corp. | August 1, 2001 | MODERATE | LOW | CLOSED | November 20, 2001 | 3.2.8 |
| 58 | Wrong Bug Number for Missing R,L,C_pkg Subparameter(s) | Lance Wang (Cadence Design Systems. Inc.) | 7/20/2001 | ANNOYING | LOW | CLOSED | July 12, 2002 | 3.2.9 |
| 57 | Non-Monotonic I-V Table Causes Waveform End Point Test Fail | Bob Ross, Mentor Graphics | June 15, 2001 | ANNOYING | LOW | CLOSED | July 12, 2002 | 3.2.9 |
| 56 | Parser Fails to Detect Always Flowing Current | Matthew Flora, Innoveda, Inc. | 6 Apr 2001 | ENHANCEMENT | LOW | CLOSED | November 20, 2001 | 3.2.8 |
| 55 | Control-Z Can be Used as End-of-File | Matthew Flora, Innoveda, Inc. | 27 Mar 2001 | ANNOYING | LOW | CLOSED | November 20, 2001 | 3.2.8 |
| 54 | Corners with NA Give Bad Test Load Warnings | Michael Mirmak, Intel Corp. | February 23, 2001 | ANNOYING | LOW | CLOSED | November 20, 2001 | 3.2.8 |
| 53 | BUG34 is Incorrectly Fixed in Version 3.2.6 | Michael Mirmak, Intel Corp. | January 8, 2001 | SEVERE | HIGH | CLOSED | March 27, 2001 | 3.2.7 |
| 52 | IBISCHK3 Hangs for [Add Submodel] Instead of [Submodel] | Michael Mirmak, Intel Corp. | December 6, 2000 | SEVERE | MEDIUM | CLOSED | November 20, 2001 | 3.2.8 |
| 51 | Error Message Needed for Missing [Submodel] | Michael Mirmak, Intel Corp. | December 6, 2000 | MODERATE | MEDIUM | CLOSED | November 20, 2001 | 3.2.8 |
| 50 | Error Message for Out of Order C_comp Values | Michael Mirmak, Intel Corp. | November 8, 2000 | ANNOYING | LOW | CLOSED | November 20, 2001 | 3.2.8 |
| 49 | Warning Message for Unreferenced Models, Submodels | Michael Mirmak, Intel Corp. | November 2, 2000 | ENHANCEMENT | LOW | CLOSED | November 20, 2001 | 3.2.8 |
| 48 | Warning Message for Vref, Cref, Rref, Vmeas in Wrong Models | Michael Mirmak, Intel Corp. | November 2, 2000 | ANNOYING | LOW | CLOSED | November 20, 2001 | 3.2.8 |
| 47 | Change Waveform Mismatch Warning to Error and Warning | Mike LaBonte, Cadence Design Systems, Matthew Flora. Innoveda, Inc. | 19 Sep 2000 | ENHANCEMENT | LOW | CLOSED | January 2, 2001 | 3.2.6 |
| 46 | Warning Message Missed for Typ Outside of Min and Max | Matthew Flora, HyperLynx | 1 Aug 2000 | ENHANCEMENT | LOW | CLOSED | January 2, 2001 | 3.2.6 |
| 45 | GND* and POWER* Nets Generate Errors in EBD Files | Michael Cohen, IBM | 07/20/2000 | MODERATE | HIGH | CLOSED | January 2, 2001 | 3.2.6 |
| 44 | Warning for Parasitic Resistance Set Too High at 1000 Ohms | Matthew Flora, HyperLynx | 7 June 2000 | ANNOYING | LOW | CLOSED | January 2, 2001 | 3.2.6 |
| 43 | Error for Zero or Negative dV/dt Ramp Data Needed | Matthew Flora, HyperLynx | 7 June 2000 | MODERATE | MEDIUM | CLOSED | January 2, 2001 | 3.2.6 |
| 42 | Warning Message for Outputs with thresholds Needed | Michael Mirmak, Intel Corp. | May 9, 2000 | ENHANCEMENT | LOW | CLOSED | January 2, 2001 | 3.2.6 |
| 41 | Issue Warning Instead of Error for Common Differential Pin | Bob Ross, Mentor Graphics (Based on discussions with Stephen Nolan, Texas Instrumens) | May 9, 2000 | ENHANCEMENT | MEDIUM | CLOSED | January 2, 2001 | 3.2.6 |
| 40 | Incorrect Error Message for Series Terminators | Bob Ross, Mentor Graphics (Originally reported by Jerry Hayes, IBM) | May 3, 2000 | SEVERE | HIGH | CLOSED | January 2, 2001 | 3.2.6 |
| 39 | No Warning is Given for Repeated Voltages in I-V Tables | Bob Ross, Mentor Graphics (Originally reported by Scott McMorrow, Siqual) | May 3, 2000 | ANNOTYING | LOW | CLOSED | January 2, 2001 | 3.2.6 |
| 38 | Ver. 2.1 File Names Greater than 8 Characters Not Reported | Bob Ross, Mentor Graphics (Originally reported by Stephen Nolan, Texas Instruments) | May 3, 2000 | MODERATE | LOW | CLOSED | January 2, 2001 | 3.2.6 |
| 37 | Pin Mapping for Unique GND or POWER Pin Generates Error | Atul P. Agarwal, Apt Software Avenues Pvt Ltd | June 17, 1999 | ANNOYING | LOW | CLOSED | January 2, 2001 | 3.2.6 |
| 36 | Reserve Words Error for Pin Mapping and Series Pin Mapping | Atul P. Agarwal, Apt Software Avenues Pvt Ltd | June 17, 1999 | ANNOYING | LOW | CLOSED | January 2, 2001 | 3.2.6 |
| 35 | Model Spec Crash Related to Vinl and Vinh Being Specified | Chris Rokusek, Viewlogic Systems | 1/13/99 | SEVERE | HIGH | CLOSED | January 1999 | 3.2.2 |
| 34 | No Error Reported for Missing V/I Tables in Output Buffers | Matthew Flora, HyperLynx | 12 Jan 1999, 27 Oct 1999 - Amended, 26 May 2000 - Amended twice | ANNOYING | LOW | CLOSED | January 2, 2001, March 27, 2001 | 3.2.6, 3.2.7 |
| 33 | Infinite Loop with Decreasing V/I Bad End Voltage | Matthew Flora, HyperLynx | 3 Nov 1998 | SEVERE | HIGH | CLOSED | January 1999 | 3.2.2 |
| 32 | Package Model Lumped and Distributed Syntax Not Correct | Bob Ross, Mentor Graphics | September 26, 1998 | SEVERE | HIGH | CLOSED | November 1998 | 3.2.1 |
| 31 | Error for [Pulldown] Decreasing Current Should be Warning | John Keifer, Intel | 8/5/98 | ENHANCEMENT | MEDIUM | CLOSED | January, 1999 | 3.2.2 |
| 30 | [Pin Mapping] Checks are too Simplistic | Atul Agarwal, Apt Software Avenues, Pvt. Ltd. | August 3, 1998 | ENHANCEMENT | MEDIUM | CLOSED | September, 1998, November, 1998 | 3.2.0, 3.2.1 |
| 29 | n\, \r, \r\n Line Terminators Need to be Handled. | Geoffrey Ellis, Cadence | July 24, 1998 | ENHANCEMENT | LOW | WILL NOT FIX | ||
| 28 | Endpoint Missed Due to Floating Point Precision | Chris Rokusek, Viewlogic | April 24, 1998 | MODERATE | MEDIUM | CLOSED | June 23, 1998, August 13, 1998 | 3.0.2, 2.1.17 |
| 27 | Line with 80 Spaces Causes Crash | Matthew Flora, HyperLynx | 8 Apr 1997 | SEVERE | HIGH | CLOSED | June 23, 1998, August 13, 1998 | 3.0.2, 2.1.17 |
| 26 | Parser Crashes when calling [Package Model] | Atul P. Agarwal, Apt Software Avenues Pvt Ltd | 12th March 1998 | SEVERE | HIGH | CLOSED | 4/98, 8/98 | 3.0.1, 2.1.17 |
| 25 | Keyword as First word in [Notes] causes Error | Arpad Muranyi, Intel | 13th March 1998 | ANNOYING | LOW | CLOSED | September 1998 | 3.2.0 |
| 24 | No Error Report in first [Define Package Model] | Atul P. Agarwal, Apt Software Avenues Pvt Ltd | 12th March 1998 | SEVERE | MEDIUM | CLOSED | 4/98, 8/98 | 3.0.1, 2.1.17 |
| 23 | An Empty [Pullup], [Pulldown] with Waveform Table Crashes | Atul P. Agarwal, Apt Software Avenues Pvt Ltd | 6th February, 1998 | SEVERE | MEDIUM | CLOSED | 3/98, 8/98 | 3.0.0, 2.1.17 |
| 22 | Empty [Rising Waveform] of [Falling Waveform] Causes Crash | Atul P. Agarwal, Apt Software Avenues Pvt Ltd | 6th February, 1998 | SEVERE | MEDIUM | CLOSED | 3/98, 8/98 | 3.0.0, 2.1.17 |
| 21 | Drive Warnings for Columns with "NA" Data | Matthew Flora, HyperLynx | 7 Jan 1998 | ANNOYING | LOW | CLOSED | January 30, 1998 | 2.1.15 |
| 20 | Crash with Multiple Filename Extensions under Windows95 | Matthew Flora, HyperLynx | 7 Jan 1998 | SEVERE | MEDIUM | CLOSES | January 30, 1998 | 2.1.15 |
| 19 | "typ" Data Outside "min" "max" Not Reported As Warning | Paul Gregory, Hewlett Packard | November 13, 1997 | ENHANCEMENT | LOW | CLOSED | 4/98, 8/98 | 3.0.1, 2.1.17 |
| 18 | Other Order R_pin, L_pin, C_pin Columns Not Correctly Read | Matthew Flora, HyperLynx | 20 Sep 1997 | MODERATE | MEDIUM | CLOSED | January 1998 | 2.115 |
| 17 | Incomplete [Pin] L_pin, C_pin, R_pin Error Message | Matthew Flora, HyperLynx | 20 Sep 1997 | ANNOYING | LOW | CLOSED | January 1998 | 2.115 |
| 16 | [Package] Argument Does Not Give Error | Matthew Flora, HyperLynx | 20 Sep 1997 | MODERATE | MEDIUM | CLOSED | January 1998 | 2.115 |
| 15 | "Program Bug" for Version 1.1 Files with more than 512 Pins | Matthew Flora, HyperLynx | 19 Sep 1997 | MODERATE | MEDIUM | CLOSED | January 1998 | 2.115 |
| 14 | Long Illegal Keyword Prints Meaningless Message | Matthew Flora, HyperLynx | 14 Sep 1997 | ANNOYING | LOW | CLOSED | January 1998 | 2.115 |
| 13 | Parser Crashes if Error in Line Longer than 256 Characters | Matthew Flora, HyperLynx | 8 Sep 1997 | ANNOYING | LOW | CLOSED | January 1998 | 2.115 |
| 12 | Lines Greater than 1024 Characters Cause Wrong Line Numbers | Matthew Flora, HyperLynx | 8 Sep 1997 | ANNOYING | LOW | CLOSED | January 1998 | 2.115 |
| 11 | Parser Continues after [End] Keyword | Matthew Flora, HyperLynx | 8 Sep 1997 | MODERATE | MEDIUM | CLOSED | January 1998 | 2.115 |
| 10 | Crash if Parser Encounters Empty V/I Table | Matthew Flora, HyperLynx | 7 Sep 1997 | SEVERE | HIGH | CLOSED | January 1998 | 2.115 |
| 9 | Crash if Keyword Associated with [Model] Comes First | Matthew Flora, HyperLynx | 7 Sep 1997 | SEVERE | HIGH | CLOSED | January 1998 | 2.115 |
| 8 | Reserved Words Used as Pin Numbers Generate Errors | Bob Ross, Interconnectix | February 6, 1997 | ANNOYING | LOW | CLOSED | 3/98, 8/98 | 3.0.0, 2.1.17 |
| 7 | Check of VI Curves Against Waveforms | Chris Rokusek, Quad Design | November 5, 1996 | ENHANCEMENT | MEDIUM | CLOSED | May, 1997 | 2.114 |
| 6 | Output Control | Chris Rokusek, Quad Design | November 5, 1996 | ENHANCEMENT | LOW | CLOSED | May 1997 | 2.114 |
| 5 | Additional Value Checking | Chris Rokusek, Quad Design | November 5, 1996 | ENHANCEMENT | MEDIUM | CLOSED | May 1997 | 2.114 |
| 4 | Printout Version No. | Bob Ross, Interconnectix, Inc. | March 11, 1996 | ENHANCEMENT | LOW | CLOSED | 4/25/96 | 2.1.11 |
| 3 | Incorrect [Model] Sub-parameter Syntax Not Reported | Bob Ross, Interconnectix, Inc. | February 21, 1996 | MODERATE | HIGH | CLOSED | 4/25/96 | 2.1.11 |
| 2 | Package Model Warning Message for Legal Suffixes | Bob Ross, Interconnectix, Inc. | February 21, 1996 | MODERATE | HIGH | CLOSED | 4/25/96 | 2.1.11 |
| 1 | Multiple Disclaimers | Bob Ross, Interconnectix, Inc. | February 21, 1996 | ANNOYING | LOW | CLOSED | 4/25/96 | 2.1.11 |
The incorporation of the bugs into the various versions of IBISCHK are shown in bugdir.txt.